Toshiba TOSVERT VF-AS1 instruction manual

Models: TOSVERT VF-AS1 VF-AS1

1 73
Download 73 pages 18.65 Kb
Page 23
Image 23

efesotomasyon.com -Toshiba inverter,drive,servo,plc

E6581315

Host computer

 

 

 

 

 

 

Block 2

 

 

 

 

Block 1

 

 

 

 

 

 

 

Inverter No.20 Inverter No.21 Inverter No.29

 

Inverter No. 10 Inverter No.11

Inverter No.19

 

 

VF-AS1

VF-AS1

VF-AS1

VF-AS1

VF-AS1

VF-AS1

*1

*1: Error signal I/F

In broadcast communication, only the representative inverter in each block returns data to the host computer. However, you can make the representative inverter in each block report the occurrence of a problem in the block. To do so, follow these steps.

Set the timer function so that, if a time-out occurs, the inverter will trip (Ex.: = (sec)), set the output terminal selection parameter (FL) so that trip information will be output through the output terminal (=), and set the input terminal selection parameter (F) of the representative in- verter in each block to “external input trip (emergency stop)” (=). Then, connect the input terminal (F, CC) of the representative inverter to the FL terminal (FLA, FLC) of each of the other in- verters in the same block (FLA-F, FLC-CC). In this setting, if an inverter trips, the representative in- verter will come to an emergency stop, and as a result it will report the occurrence of a problem in its block to the computer. (If the representative inverter returns a lowercase letter in response to a command from the computer, the computer will judge that a problem has arisen in an inverter.) To examine details on the problem that has arisen, the host computer accesses each individual inverter, specifying its communication number. To make the computer issue a command to all inverters in block 1 or block 2 shown in the figure above, specify “1*” or “2*”, respectively. In this system, inverter No. 10 will return data to the computer if a problem arises in block 1, or inverter No. 20 if a problem arises in block 2. For overall broadcast communication, specify “**”, in which case the inverter with the communication number “00” will return data to the computer.

In this example, if you want the computer to maintain communication without bringing an represen- tative inverter to an emergency stop, set its input terminal selection parameter to “disabled (=) but not to “external input trip (emergency stop).” This setting causes the host computer to check the setting of the input terminal information parameter (Communication No.=DF06, bit 0) of the representative inverter, and as a result enables the computer to detect the occurrence of a problem.

CAUTION:

Data from inverters will be deformed if inverters of the same number are connected on the network. Never assign same single numbers to inverters on the network.

22

Page 23
Image 23
Toshiba TOSVERT VF-AS1 instruction manual