efesotomasyon.com -Toshiba inverter,drive,servo,plc

E6581315

7.4.Send waiting time (, )

Use this function for the following case:

When the data response from the inverter is too quick after the PC had sent the data to the inverter, PC process cannot get ready to receive the data, or when the USB/RS485, RS485/RS232C con- verter is used, changeover of sending and receiving data takes much time in the converter process.

Functional specification:

A time for sending data is prolonged longer than the preset time (, ), until the inverter returns the data to the PC, after it finishes receiving the data (in case of an inter-drive communica- tion, until the inverter returns the next data to the PC, after it has sent the data.) In case the inverter's processing capacity requires longer setting time, the value more than this time will be the set value. (The parameter makes the inverter wait for more than the set time.)

Setting range:  to seconds (10ms to 2000ms)

If the set value is , this function becomes invalid and the interval time for sending data is set to the maximum capacity of the inverter. To obtain a quick response for sending data, set value .

Computer link

PC→INV

 

Time elapses more than

 

 

transmission waiting time.

 

 

 

 

 

 

 

 

 

 

INV→PC

 

 

 

 

 

Inter-drive

Master INV

 

 

 

communication

to Slave INV

 

 

 

 

Time

elapses more than the

Master INV to

 

Slave INV

 

transmission waiting time.

 

7.5. Free notes()

This parameter allows you to write any data, e.g., the serial number of each inverter or parameter information, which does not affect the operation of the inverter.

44

Page 45
Image 45
Toshiba TOSVERT VF-AS1 Send waiting time , , Free notes, Use this function for the following case