efesotomasyon.com -Toshiba inverter,drive,servo,plc

E6581315

Appendix 2 Response time

The communication response time can be calculated from data communication time and inverter processing time. When wishing to know the communication response time, calculate using the following as a reference

Interval corresponding to 3.5 bytes

Data transmission time

Data processing time of inverter (Approx. 8 ms)

PC Inverter

Data transmission time

Inverter PC

Response time

„ Data transmission time

1

 

Data transmission time = baud rate

number of bytes transmittednumber of bits

*Number of bits = start bit + data frame length + parity bit + stop bit

*Minimum number of bits = 1 + 8 + 0 + 1 = 10 bits

*Maximum number of bits = 1 + 8 + 1 + 2 = 12 bits

<An example of the calculation of the transmission time: 19200 bps, 8 bytes, 11 bits>

Data transmission time =

1

8 11 = 4.6ms

19200

„Data processing time of inverter Data processing time: maximum 8 ms