Inverter operating command mode status (FD45, FE45)
The monitor of the command mode that the present condition is enabled
Command mode status (current status): “Communication Number FD45”
Command mode status (status immediately before the occurrence of a trip): “Communication Num-
ber
Data Enabled command
0 Terminal input enabled
1 Operation panel input enabled
2 Operation panel RS485 (2-wire) communication input
3 Internal RS485 (4-wire) communication input
4 Communication option input
Inverter operating frequency mode status (FD46, FE46)
The monitor of the frequency command mode that the present condition is enabled
Note that Preset speed operation frequencies is given the priority independent of the frequency
mode, in which case this monitor will be disabled, in case Preset speed operation frequencies is
selected.
Frequncy mode status (current status): Communication Number FD46
Frequncy mode status (status immediately before the occurrence of a trip):Communication
Number FE46
Data Enabled frequency
1 VI/II input
2 RR/S4 input
3 RX input
4 Operation panel input enabled
5 Operation panel RS485 (2-wire) communication input
6 Internal RS485 (4-wire) communication input
7 Communication option input
8 Optional AI1
9 Optional AI2
10 UP/DOWN frequency
11 RP pulse input
12 High-speed pulse input
13 Binary/BCD input
255 Preset speed operation