„Inverter operating status 1 (FD01, FE01)

Inverter status 1 (current status): Communication Number FD01

Inverter status 1 (status immediately before the occurrence of a trip): Communication Number FE01

Bit

Specifications

0

1

Remarks

 

0

Failure FL

No output

Output in progress

 

 

 

1

Failure

Not tripped

Tripped

Trip statuses

include



 

 

 

 

and trip retention status.

 

2

Alarm

No alarm

Alarm issued

 

 

 

3

Reserved

-

-

 

 

 

4

Motor section (1 or 2)

Motor 1 (THR 1)

Motor 2 (THR 2)

 

 

 

 

(THR 2 selection)

 

 

 

 

 

5

PI control OFF

PI control

PI control

 

 

 

 

 

permitted

prohibited

 

 

 

6

Accelera-

Acceleration/

Acceleration/

AD1 :, 

 

 

tion/deceleration

deceleration

deceleration pat-

AD2 :, 

 

 

pattern selection (1 or

pattern 1 (AD 1)

tern 2 (AD 2)

 

 

 

 

2)

 

 

 

 

 

7

DC braking

OFF

Forced DC braking

 

 

 

8

Jog run

OFF

Jog run

 

 

 

9

Forward/reverse run

Forward run

Reverse run

 

 

 

10

Run/stop

Stop

Run

 

 

 

11

Coast stop (ST=OFF)

ST=ON

ST=OFF

 

 

 

12

Emergency stop

Not emergency

Emergency stop

 

 

 

 

 

stop status

status

 

 

 

13

Standby ST=ON

Start-up process

Standby

Standby: Initialization completed,

 

 

 

 

not failure stop status, not alarm

 

 

 

 

stop status (MOFF, LL forced

 

 

 

 

stop or forced stop due to a

 

 

 

 

momentary

power

failure),

 

 

 

 

ST=ON, and RUN=ON

 

14

Standby

Start-up process

Standby

Standby: Initialization completed,

 

 

 

 

not failure stop status, and not

 

 

 

 

alarm stop status (MOFF, LL

 

 

 

 

forced stop or forced stop due to

 

 

 

 

a momentary power failure)

15

Reserved

-

-

 

 

 