Toshiba TOSVERT VF-AS1 instruction manual Inv-No

Models: TOSVERT VF-AS1 VF-AS1

1 73
Download 73 pages 18.65 Kb
Page 17
Image 17

efesotomasyon.com -Toshiba inverter,drive,servo,plc

E6581315

2) Error Processing (Binary mode)

In case an error occurs, communication error command (4EH(N) or 6EH(n)) and the error type num- ber is returned to the computer in addition to the checksum.

Omissible

 

(3.5bytes

“/”

 

INV-NO

 

Norn

DATA

 

SUM

(3.5bytes

 

 

Blank)

(2FH)

 

1 byte

 

(4EH)(6EH)

2 bytes

 

1 byte

Blank)

 

 

 

 

 

 

 

 

Checksum area

 

Not omissible

 

 

 

 

 

 

“N” or “n” (1 byte)

: Communication error command. Also for check during an inverter trip (includes standing

 

 

 

by for retrying and trip holding). “4EH (N)” when normal, “6EH (n)” during an inverter trip.

DATA (2 bytes)

 

: Error code (0004)

 

 

 

 

 

 

 

 

 

 

0004

: Checksum error (The checksum does not match)

 

 

 

 

 

No return : Command error, format error (specified number of bytes is not received in 1sec,

 

 

 

 

 

or parity error, overrun error or framing error), inverter number mismatch, and

 

 

 

 

 

inverter number other than 00H in broadcast communication.

„ Examples

 

 

 

 

 

 

 

 

 

 

 

 

Computer → Inverter

: 2F 58 02 05 C4 00 17 70 D8

 

 

 

 

 

 

Inverter → Computer

: 2F 4E 00 04 81 ... Checksum error

 

 

 

 

 

 

16

Page 17
Image 17
Toshiba TOSVERT VF-AS1 instruction manual Inv-No