Replacement Procedures
Installing the LCD unit/FL Inverter
The following describes the procedure for installing the LCD unit and FL inverter.
Install the LCD supports (LCD unit side) and hinge to the LCD and secure them with the following screws.
∙ M2.0×2.5 BINK screw | x8 |
1.Stand the LCD unit on the display cover and connect the LCD harness to the connector on the back of LCD.
2.Stick the conductive tape on the connector of LCD harness.
3.Secure the LCD unit with the following screws.
∙ | M2.5x4.0 | screw | x2 |
∙ | M2.5x5.0 | screw | x8 |
4. Connect LCD harnesses to the connector CN1 of the inverter.
CAUTION: Be careful not to connect the LCD harnesses to the wrong connectors of FL inverter.
5.Connect HV harnesses to the connector CN2 of the FL inverter.
6.Install the display mask while fitting the latches.
7.Secure the display mask with following screws
M2.5×6.5 screw X8
8. Cover screws with Screw MYLAR cover X8
NOTE: When installing the display mask, make sure there is no gap between the display mask and the display cover.
Qosmio X500 Maintenance Manual |