Transition Networks

SISGM1040-162D-LR

Fault Relay Alarm

The Fault Relay Alarm function provides the mechanism for warning when power or port faults are detected. There is a set of relay contacts in the switch, and the contacts are closed when either no fault alarms are configured, or the system is normal. With the check boxes unchecked, the system won’t change the status of the relay when a fault occurs. Please see the segment of ‘Wiring the Fault Alarm Contact’ for reference. With both power input 1 and power input 2 installed and the check boxes of power 1/power 2 ticked, the FAULT LED indicator will then be possible to light up when any one of the power fault occurs. As for the Port Link Down/Broken detection, the FAULT LED indicator will light up when the port fault occurs.

￿Power Failure: Tick the check box to enable the function of lighting up the FAULT LED on the panel when power fails.

￿Port Link Down/Broken: Tick the check box to enable the function of lighting up FAULT LED on the panel when Ports’ states are link down or broken.

Fault Relay Alarm interface

Technical Support: 1-800-260-1312

International: 00-1-952-941-7600

61

Page 68
Image 68
Transition Networks SISGM1040-162D manual Fault Relay Alarm