Troubleshooting

Transition Networks

SISGM1040-162D-LR

Troubleshooting

￿Verify the switch is using the right power cord/adapter (DC 12-48V), please don’t use the power adapter with DC voltage higher than 48V, or it may damage the switch.

￿Select the proper UTP cable to construct user network. Please check that is using the right cable. Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Manual background Category 3, 4 or 5 cable for 10Mbps connections, 100

Manual background Category 5 cable for 100Mbps connections, or 100Manual background Category 5e/6 cable for

1000Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).

￿Diagnosing LED Indicators: The Switch can be easily monitored through panel indicators, which indicate common problems. Check the switch panel LEDs to assist in identifying problems.

￿If the power indicator does not light on when the power cord is plugged in, there may be a problem with the power cord. Check for loose power connections, power losses or surges at power outlet. If user still cannot resolve the problem, contact user local dealer for assistance.

￿If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit, Please check configuration or status.

Technical Support: 1-800-260-1312

International: 00-1-952-941-7600