F3200 Installation & Programming Manual

 

New Zealand Operation

MIMIC DISPLAY (CONTINUED)

LM0092 LOOM, CONTROLLER TO FIRST DISPLAY, 1.2m

PA0483 PCB ASSY, IOR UNPROTECTED TERMINATION BOARD

PA0499 PCB ASSY, NZ DISPLAY EXTENDER BOARD

PA0769 PCB ASSY,16 O/P MIMIC TERMINATION BOARD,C/W RESISTORS (As for PA0483 but 3k3 resister per output)

PA0753 PCB ASSY,PICTURE FRAME DISPLAY,16 LED MIMIC,24V

PA0760 PCB ASSY,NZ DISPLAY EXTENDER,PFD MIMIC

Suitable cabinets for Mimic Displays include:

ME0073 PICTURE FRAME DISPLAY,F/S, EMPTY,003 LOCK,C/W INDEX

ME0074 PICTURE FRAME DISPLAY,F/S,EMPTY,60124 LOCK,C/W INDEX

ME0076 PICTURE FRAME DISPLAY,R/S,EMPTY,60124 LOCK,C/W INDEX

or various FP1600/OMEGA 64 empty cabinets and the PA0787 FP1600 Mimic Display Board provide an alternative format.

At the display panel there are two possibilities:

(i)Geographic Plan Mimic - the FRCs from the NDU are connected to Termination boards (PA0483). Individual LEDs with series resistors are mounted on the display panel and wired to these Termination boards. Figure 12.8.1 shows this arrangement. Alternatively, the PA0769 Termination Board has 3k3 resistors already fitted (gives 7mA LED current which is adequate for interior use).

(ii)Column Format - where arrangement of zone alarms into columns is acceptable, LED Mimic Display boards can be used. This simplifies the wiring considerably.

The Picture Frame Display (ME0074 or ME0073 Front Service, or ME0076 Rear Service) is a suitable cabinet, and also has mounting hardware for four 16 zone Display mimic boards (PA0753), plus one Common Indicator and Index Lamp Mimic board (PA0760). Figure 12.8.2 shows this arrangement.

Note that a special 3-way FRC is required for the Display Extender board, so that the miscellaneous inputs are accessible in the NDU cabinet. This is not a standard part, and will need to be made up to suit the application.

12.8.3ACTIVE DISPLAY

An active display is driven from the NDU display chain and is economical for large mimics. The Picture Frame Display (PFD) cabinet is suitable for housing an active display with a 12 way shielded cable linking it to the NDU (ref. Figures 12.8.3 and 12.8.4). No supervision requirements for this cable are specified in NZS 4512, but because some individual wires in the cable are not supervised (though the cable as a whole is), good fire alarm practice dictates that the distance between the panel and indicating unit should be limited for principal brigade mimics. The wiring should also be well protected by conduit, trunking or equivalent. An electrical limit of 30 metres applies to this connection.

The following parts are available for constructing displays of this type:

PA0742 PFD NZ DISPLAY EXTENDER BOARD,24V

PA0741 PFD DISPLAY 16 ALARM LED,24V (ALARM LEDS ONLY)

PA0754 PFD 16 ZONE,FULL STATUS,24V (ALL LEDS)

FP0646 16 ZONE ALARM KIT (PA0741,FRC LOOM,POWER LEADS)

Issue 2.7

5 July 2001

Page 12-11

Page 247
Image 247
Tyco F3200 manual Active Display

F3200 specifications

The Tyco F3200 series is a sophisticated fire alarm control panel designed for use in various commercial and industrial settings. Renowned for its reliability and ease of use, the Tyco F3200 stands out for its advanced features and state-of-the-art technology, making it a preferred choice for fire safety professionals.

One of the key features of the Tyco F3200 is its modular design, which allows for customization based on specific building requirements. This flexibility enables users to scale the system efficiently, with the capability to connect multiple panels in a network configuration. This adaptability is crucial for large facilities that require comprehensive coverage across expansive areas.

The F3200 utilizes a microprocessor-based control technology that ensures swift processing and response times. This technology enhances the panel's ability to monitor and manage alarms, alerts, and system status, ensuring that users receive real-time updates and notifications in the event of an emergency. The intuitive user interface, characterized by a clear display and user-friendly controls, simplifies the operation process, making it easier for staff to manage the fire alarm system effectively.

Additionally, the Tyco F3200 is compatible with various detection devices, including smoke detectors, heat detectors, and manual pull stations. This compatibility means that the system can be tailored to meet specific safety needs, accommodating a wide array of environments. Furthermore, the panel supports both conventional and addressable devices, providing flexibility in system design.

Another significant advantage of the Tyco F3200 is its advanced communication capabilities. The panel can integrate with various alarm transmission technologies, including RS-232 and RS-485 interfaces, allowing for seamless communication with remote monitoring stations. This feature enhances the reliability of emergency response efforts.

Moreover, the F3200 includes robust diagnostic and reporting tools that help maintenance personnel ensure the system's optimal performance. It provides comprehensive event logs and troubleshooting features, allowing for easy identification of issues and efficient maintenance procedures.

In summary, the Tyco F3200 is an advanced fire alarm control panel that integrates cutting-edge technology, flexibility, and user-friendliness. Its modular design, quick response time, compatibility with various devices, and strong communication capabilities make it an excellent choice for anyone seeking a dependable fire alarm system. Whether for small businesses or large-scale operations, the F3200 delivers essential fire safety solutions tailored to meet the diverse needs of its users.