Tyco F3200 manual LM0042,LOOM,1888-62,PROG Port to 25 PIN Serial

Models: F3200

1 284
Download 284 pages 12.77 Kb
Page 52
Image 52

F3200 Installation & Programming Manual

Document No: LT0122

Ordering Information

 

ORDERING INFORMATION (CONTINUED)

LM0042,LOOM,1888-62,PROG PORT TO 25 PIN SERIAL

(cable to connect printer/computer to Controller, has 25 pin min D)

LM0044,LOOM,1901-81-1,DISPLAY EXTENDER FRC,2M

LM0045,LOOM,1901-81-2,DISPLAY EXTENDER FRC,5M

LM0046,LOOM,1901-81-3,DISPLAY EXTENDER FRC,0.5M

LM0049,LOOM,1901-81-4,DISPLAY EXTENDER FRC,0.25M

LM0053,LOOM,1931-28-1,F3200 20 WAY FRC,300MM

(standard FRC for interconnecting 8 way modules, included in FP0553, 554)

LM0092,LOOM 1901-88 CONTROLLER TO 1ST DISPLAY, FRC, 1.2M

(connects Display Bd to Controller, allows mounting of Display Bd in furthest left position, included with FZ3031).

LT0119 LITERATURE,1931-17,F3200 OPERATOR'S MANUAL,A4,LOOSE

LT0120 LITERATURE,1931-18,F3200 OPERATOR'S MANUAL,A5

LT0121 LITERATURE,1931-19,F3200 TECHNICAL MANUAL

LT0122 LITERATURE,1931-20,F3200 PROGRAMMING & INSTALLATION MANUAL

LT0130 LITERATURE,1931-32,F3200 PRESENTATION,ACAD12 DISK

LT0133 LITERATURE,1931-46,REMOTE LCD UNIT,OPERATOR MANUAL,A4

LT0135 LITERATURE,1931-52,F3200 ARCHITECTS SPEC,A4

LT0148 LITERATURE,1931-64,RDU INSTALLATION & PROGRAM MANUAL

LT0212 LITERATURE,RDU TO NDU UPGRADE INSTRUCTIONS

ME0060,MECH ASSY,1901-79,RAC CABINET,EXT INNER DOOR

(hinged 7U inner door for mounting Display Bds on, includes screws, perspex window, cage nuts and pcb standoffs)

ME0063,MECH ASSY,1931-15-1,F3200 4U HINGED CONTROL PANEL (4U hinged door with keypad and Controller/Display pcb mounted on it).

ME0064,MECH ASSY,1931-15-1,F3200 4U HINGED RDU CONTROL PANEL

(4U hinged door with no-name keypad and RDU Controller/Display mounted on it).

ME0065,MECH ASSY,1931-47,1 ZONE GAS CONTROL 7U DOOR

ME0066,MECH ASSY,1931-47,2 ZONE GAS CONTROL 7U DOOR

ME0067,MECH ASSY,1931-47,3 ZONE GAS CONTROL 7U DOOR

ME0068,MECH ASSY,1931-47,4 ZONE GAS CONTROL 7U DOOR

(ME0065-68 include screened 7U door, field connector and looms for connecting to 8RMS and 8ZMs, screws and cage nuts - for 1,2,3 or 4 gas zones)

Page 4-4

5 July 2001

Issue 2.7

Page 52
Image 52
Tyco F3200 manual LM0042,LOOM,1888-62,PROG Port to 25 PIN Serial, LM0092,LOOM 1901-88 Controller to 1ST DISPLAY, FRC, 1.2M

F3200 specifications

The Tyco F3200 series is a sophisticated fire alarm control panel designed for use in various commercial and industrial settings. Renowned for its reliability and ease of use, the Tyco F3200 stands out for its advanced features and state-of-the-art technology, making it a preferred choice for fire safety professionals.

One of the key features of the Tyco F3200 is its modular design, which allows for customization based on specific building requirements. This flexibility enables users to scale the system efficiently, with the capability to connect multiple panels in a network configuration. This adaptability is crucial for large facilities that require comprehensive coverage across expansive areas.

The F3200 utilizes a microprocessor-based control technology that ensures swift processing and response times. This technology enhances the panel's ability to monitor and manage alarms, alerts, and system status, ensuring that users receive real-time updates and notifications in the event of an emergency. The intuitive user interface, characterized by a clear display and user-friendly controls, simplifies the operation process, making it easier for staff to manage the fire alarm system effectively.

Additionally, the Tyco F3200 is compatible with various detection devices, including smoke detectors, heat detectors, and manual pull stations. This compatibility means that the system can be tailored to meet specific safety needs, accommodating a wide array of environments. Furthermore, the panel supports both conventional and addressable devices, providing flexibility in system design.

Another significant advantage of the Tyco F3200 is its advanced communication capabilities. The panel can integrate with various alarm transmission technologies, including RS-232 and RS-485 interfaces, allowing for seamless communication with remote monitoring stations. This feature enhances the reliability of emergency response efforts.

Moreover, the F3200 includes robust diagnostic and reporting tools that help maintenance personnel ensure the system's optimal performance. It provides comprehensive event logs and troubleshooting features, allowing for easy identification of issues and efficient maintenance procedures.

In summary, the Tyco F3200 is an advanced fire alarm control panel that integrates cutting-edge technology, flexibility, and user-friendliness. Its modular design, quick response time, compatibility with various devices, and strong communication capabilities make it an excellent choice for anyone seeking a dependable fire alarm system. Whether for small businesses or large-scale operations, the F3200 delivers essential fire safety solutions tailored to meet the diverse needs of its users.