Document No: LT0122

 

 

 

F3200 Installation & Programming Manual

 

 

 

 

 

 

 

 

 

 

Appendix A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BASES COMPATIBLE WITH DETECTORS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DET/

Z51B

Z52B

Z54B

Z55B

Z56

Z56N

Z500

Z500

Z91C

Z94

 

BASE

 

 

&

 

 

 

 

N

&

&

 

 

 

 

Z54B

 

 

 

 

 

Z94C

MH2

 

 

 

 

MK2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C24B

&

X

&

X

&

 

&

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C29B

&

X

&

X

&

 

&

 

 

'

 

 

 

 

 

 

 

 

 

 

 

 

 

C29B

 

X

 

X

 

 

 

 

&

 

 

Ex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P24B

&

X

&

X

&

 

&

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P29B

&

X

&

X

&

 

&

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T56B

&

&

&

&

&

&

&

&

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table IV

Grinnell Detector/Base Range

&These detector/base combinations are compatible.

XThese detector base combinations have been used in the past, however they are technically incorrect (see Product Bulletin PBD0004).

'The combination of Z94 base and MH2 heater unit is not SSL approved.

Note that Z52, Z55, Z56N and Z500N are non-electronic bases (ie. non-latching, non- indicating) and do not add any extra voltage to the detector in alarm (eg. if a T56B heat detector is used with these, it shorts directly across the AZC).

╔═════════════════════════════════════════════════════════╤═══════╗

DETECTORS COMPATIBLE WITH F3200 FIP│MAX NO.║

╟─────────┬───────────────────────────────────────────────┼───────╢

║ TYPE │DESCRIPTION│ 4mA ║

╠═════════╪═══════════════════════════════════════════════╪═══════╣

DCD-A │(DCC-A & DCA-B-60R) HEAT DETECTOR TYPE A │ 40 ║

╟─────────┼───────────────────────────────────────────────┼───────╢

DCD-C │(DCC-C & DCA-B-90R) HEAT DETECTOR TYPE C │ 40 ║

╟─────────┼───────────────────────────────────────────────┼───────╢

DFJ-60B │(DFE-60B & DFB-60B) HEAT DETECTOR TYPE B │ 40 ║

╟─────────┼───────────────────────────────────────────────┼───────╢

DFJ-90D │(DFE-90D & DFB-90D) HEAT DETECTOR TYPE D │ 40 ║

╟─────────┼───────────────────────────────────────────────┼───────╢

SIJ-ASN │(SIH-AM & SIF-A)IONISATION SMOKE DETECTOR │ 40 ║

╟─────────┼───────────────────────────────────────────────┼───────╢

SLR-AS │(SLK-A & SLG-AM) PHOTOELECTRIC SMOKE DETECTOR │

40 ║

╟─────────┼───────────────────────────────────────────────┼───────╢

HF-24A │ULTRAVIOLET FLAME DETECTOR│ 18 ║

╟─────────┴───────────────────────────────────────────────┴───────╢

ALL WITH YBC-RL/4AH4, YBF-RL/4AH4 OR YBF-RL/4AH4M OR YBO-R/4A

BASE

╚═════════════════════════════════════════════════════════════════╝

Table V

HOCHIKI Detector Range

Issue 2.7

5 July 2001

Page A-3

Page 259
Image 259
Tyco F3200 manual Grinnell Detector/Base Range, Hochiki Detector Range

F3200 specifications

The Tyco F3200 series is a sophisticated fire alarm control panel designed for use in various commercial and industrial settings. Renowned for its reliability and ease of use, the Tyco F3200 stands out for its advanced features and state-of-the-art technology, making it a preferred choice for fire safety professionals.

One of the key features of the Tyco F3200 is its modular design, which allows for customization based on specific building requirements. This flexibility enables users to scale the system efficiently, with the capability to connect multiple panels in a network configuration. This adaptability is crucial for large facilities that require comprehensive coverage across expansive areas.

The F3200 utilizes a microprocessor-based control technology that ensures swift processing and response times. This technology enhances the panel's ability to monitor and manage alarms, alerts, and system status, ensuring that users receive real-time updates and notifications in the event of an emergency. The intuitive user interface, characterized by a clear display and user-friendly controls, simplifies the operation process, making it easier for staff to manage the fire alarm system effectively.

Additionally, the Tyco F3200 is compatible with various detection devices, including smoke detectors, heat detectors, and manual pull stations. This compatibility means that the system can be tailored to meet specific safety needs, accommodating a wide array of environments. Furthermore, the panel supports both conventional and addressable devices, providing flexibility in system design.

Another significant advantage of the Tyco F3200 is its advanced communication capabilities. The panel can integrate with various alarm transmission technologies, including RS-232 and RS-485 interfaces, allowing for seamless communication with remote monitoring stations. This feature enhances the reliability of emergency response efforts.

Moreover, the F3200 includes robust diagnostic and reporting tools that help maintenance personnel ensure the system's optimal performance. It provides comprehensive event logs and troubleshooting features, allowing for easy identification of issues and efficient maintenance procedures.

In summary, the Tyco F3200 is an advanced fire alarm control panel that integrates cutting-edge technology, flexibility, and user-friendliness. Its modular design, quick response time, compatibility with various devices, and strong communication capabilities make it an excellent choice for anyone seeking a dependable fire alarm system. Whether for small businesses or large-scale operations, the F3200 delivers essential fire safety solutions tailored to meet the diverse needs of its users.