Document No: LT0122

F3200 Installation & Programming Manual

 

Programming

6.4PROGRAM DATA MENU, TEXT & GLOBAL

PARAMETERS

6.4.1GENERAL

The Program Data menu (refer to Fig 6.1.2) allows the user to program the following options:

1:Access Codes; 2:Text; 3:Global Data; 4:System Configuration; and 5:DBload.

Option 5:DBload is described in Section 6.3.5, and System Configuration is described in Chapter 7. Option 3:Global Data is described in Section 6.4.4. The other options are described in the following sections.

A summary of the programmable options and their default values is shown in Table 6.4.1 at the end of this chapter.

6.4.2ACCESS CODES

Up to 10 separate 6 digit access codes are available (numbered 0-9), and each one has provision for the users' initials (3 characters). The initials of the last user to change the database are stored in the database. When the database is de-accessed, the user number and initials are logged with the event.

The default access code for user 0 is 000000. There is no default code for users 1-9. User

0 can change any access codes (users 0-9), but users 1-9 can change only their own access code.

To enter or edit an access code, enter the user number (0-9) from the keypad. This gives the options of: 1 : Access Code; 2 : Initials; 3 : Delete.

1.To enter a New Access Code, select Option 1. Enter the new six digits, and then re- enter them to confirm.

2.To enter The New Three initials, select Option 2.

The LCD will display the alphabet on the bottom line. Move the cursor through the alphabet using the ! " cursor keys. Press "ENTER" when the desired letter is selected. Press "ACK" to save the entered initials.

"DELETE" will delete an entry. "EDIT" will toggle the cursor between the top line (initials) and the bottom line (alphabet).

3.To Delete an Access Code, select Option 3 for that user. Press "ACK" to remove the code for that user. The initials remain but can be edited as in 2 above.

Note that no two users should have the same code. Access code 000000 should not be used for any user as it will be known by all service people familiar with F3200.

Issue 2.7

5 July 2001

Page 6-17

Page 83
Image 83
Tyco F3200 manual Program Data MENU, Text & Global Parameters, Access Codes

F3200 specifications

The Tyco F3200 series is a sophisticated fire alarm control panel designed for use in various commercial and industrial settings. Renowned for its reliability and ease of use, the Tyco F3200 stands out for its advanced features and state-of-the-art technology, making it a preferred choice for fire safety professionals.

One of the key features of the Tyco F3200 is its modular design, which allows for customization based on specific building requirements. This flexibility enables users to scale the system efficiently, with the capability to connect multiple panels in a network configuration. This adaptability is crucial for large facilities that require comprehensive coverage across expansive areas.

The F3200 utilizes a microprocessor-based control technology that ensures swift processing and response times. This technology enhances the panel's ability to monitor and manage alarms, alerts, and system status, ensuring that users receive real-time updates and notifications in the event of an emergency. The intuitive user interface, characterized by a clear display and user-friendly controls, simplifies the operation process, making it easier for staff to manage the fire alarm system effectively.

Additionally, the Tyco F3200 is compatible with various detection devices, including smoke detectors, heat detectors, and manual pull stations. This compatibility means that the system can be tailored to meet specific safety needs, accommodating a wide array of environments. Furthermore, the panel supports both conventional and addressable devices, providing flexibility in system design.

Another significant advantage of the Tyco F3200 is its advanced communication capabilities. The panel can integrate with various alarm transmission technologies, including RS-232 and RS-485 interfaces, allowing for seamless communication with remote monitoring stations. This feature enhances the reliability of emergency response efforts.

Moreover, the F3200 includes robust diagnostic and reporting tools that help maintenance personnel ensure the system's optimal performance. It provides comprehensive event logs and troubleshooting features, allowing for easy identification of issues and efficient maintenance procedures.

In summary, the Tyco F3200 is an advanced fire alarm control panel that integrates cutting-edge technology, flexibility, and user-friendliness. Its modular design, quick response time, compatibility with various devices, and strong communication capabilities make it an excellent choice for anyone seeking a dependable fire alarm system. Whether for small businesses or large-scale operations, the F3200 delivers essential fire safety solutions tailored to meet the diverse needs of its users.