Tyco F3200 manual NDU Quiescent and Alarm Currents

Models: F3200

1 284
Download 284 pages 12.77 Kb
Page 35
Image 35

Document No: LT0122

F3200 Installation & Programming Manual

 

System Specifications

3.3.5.2NDU Quiescent and Alarm Currents

Slimline NDU (FP0714/FP0773/FP07744)

Operating Voltage

:

24Vdc (18-28V)

Termination

:

For up to 2.5sqmm TPS

 

 

Quiescent

Alarm

Current Consumption :

25mA

80mA

Full cabinet NDU (FP0715)

Quiescent

Alarm

Current Consumption (Aust mode)1

70mA

165mA

Current Consumption (NZ mode)2

85mA

150mA

1.Includes controller, MAF/PSU, energised standby relay, PA0773 RS485 Bd, LCD backlight off in quiescent state.

2.Includes controller, MAF/PSU, NZ Display Extender, energised standby and alarm relays, PA0773 RS485 Bd. LCD backlight off in quiescent state.

3.Refer to Section 3.3.5.1 for additional module currents.

4.For FP0774 the I-Hub currents must be added.

Issue 2.7

5 July 2001

Page 3-7

Page 35
Image 35
Tyco F3200 manual NDU Quiescent and Alarm Currents

F3200 specifications

The Tyco F3200 series is a sophisticated fire alarm control panel designed for use in various commercial and industrial settings. Renowned for its reliability and ease of use, the Tyco F3200 stands out for its advanced features and state-of-the-art technology, making it a preferred choice for fire safety professionals.

One of the key features of the Tyco F3200 is its modular design, which allows for customization based on specific building requirements. This flexibility enables users to scale the system efficiently, with the capability to connect multiple panels in a network configuration. This adaptability is crucial for large facilities that require comprehensive coverage across expansive areas.

The F3200 utilizes a microprocessor-based control technology that ensures swift processing and response times. This technology enhances the panel's ability to monitor and manage alarms, alerts, and system status, ensuring that users receive real-time updates and notifications in the event of an emergency. The intuitive user interface, characterized by a clear display and user-friendly controls, simplifies the operation process, making it easier for staff to manage the fire alarm system effectively.

Additionally, the Tyco F3200 is compatible with various detection devices, including smoke detectors, heat detectors, and manual pull stations. This compatibility means that the system can be tailored to meet specific safety needs, accommodating a wide array of environments. Furthermore, the panel supports both conventional and addressable devices, providing flexibility in system design.

Another significant advantage of the Tyco F3200 is its advanced communication capabilities. The panel can integrate with various alarm transmission technologies, including RS-232 and RS-485 interfaces, allowing for seamless communication with remote monitoring stations. This feature enhances the reliability of emergency response efforts.

Moreover, the F3200 includes robust diagnostic and reporting tools that help maintenance personnel ensure the system's optimal performance. It provides comprehensive event logs and troubleshooting features, allowing for easy identification of issues and efficient maintenance procedures.

In summary, the Tyco F3200 is an advanced fire alarm control panel that integrates cutting-edge technology, flexibility, and user-friendliness. Its modular design, quick response time, compatibility with various devices, and strong communication capabilities make it an excellent choice for anyone seeking a dependable fire alarm system. Whether for small businesses or large-scale operations, the F3200 delivers essential fire safety solutions tailored to meet the diverse needs of its users.