Tyco F3200 manual Text Entry, Programming Text with the Keypad, Prev

Models: F3200

1 284
Download 284 pages 12.77 Kb
Page 84
Image 84

F3200 Installation & Programming Manual

Document No: LT0122

Programming

 

 

6.4.3

TEXT ENTRY

 

The Text option allows entry of the following:

1.a 40 character name for the site

2.a 30 character name for each zone

3.a 30 character name for each module relay

4.a 30 character name for each ancillary relay

5.a 6 character name for each of the 9 programmable alarm text messages.

6.a 40 character fault action text.

7.a 12 character Tandem LCD password.

Text can be programmed with the keypad or with a PC connected to the Printer/Programmer port (refer Section 6.4.3.2).

6.4.3.1PROGRAMMING TEXT WITH THE KEYPAD

When an item (e.g. Zone 01) is selected, press "EDIT", "ENTER" or """ to enable text entry for that item.

Text entry has two fields. The top field contains the text which has been entered and the bottom field contains an array of characters which may be entered.

Each field has one of two cursors. The active cursor may be moved through the field it is in by use of the ! " cursor keys to select a character, or position in text. The inactive cursor

$shows where the active cursor would be if it was in that field. Holding the ! " keys down causes rapid movement.

There is a choice of 3 lines of characters in the bottom field (upper case letters, lower case letters, numbers and symbols). These may be scrolled by use of the # and % cursor keys when the active cursor is in the bottom line. Note that numbers can be entered directly from the keypad, and the "NOT" key inserts a blank space.

"EDIT" swaps the cursors between the two fields.

"INSERT" toggles entry between "insert" and "typeover" modes.

"DELETE" acts as backspace for a character just entered, or deletes any character in the text selected by the cursor (active or inactive).

"ACK" saves the text and returns the cursor to the item number.

"NEXT" & step through items (e.g. zones).

"PREV"

"RECALL" allows copying of the text from any zone or relay to any other zone or relay. (Select zone/relay to be copied into. Press "RECALL" and select zone/relay and number of zone/relay to be copied from. "ENTER" transfers the text.

This can then be edited).

Page 6-18

5 July 2001

Issue 2.7

Page 84
Image 84
Tyco F3200 manual Text Entry, Programming Text with the Keypad, Prev

F3200 specifications

The Tyco F3200 series is a sophisticated fire alarm control panel designed for use in various commercial and industrial settings. Renowned for its reliability and ease of use, the Tyco F3200 stands out for its advanced features and state-of-the-art technology, making it a preferred choice for fire safety professionals.

One of the key features of the Tyco F3200 is its modular design, which allows for customization based on specific building requirements. This flexibility enables users to scale the system efficiently, with the capability to connect multiple panels in a network configuration. This adaptability is crucial for large facilities that require comprehensive coverage across expansive areas.

The F3200 utilizes a microprocessor-based control technology that ensures swift processing and response times. This technology enhances the panel's ability to monitor and manage alarms, alerts, and system status, ensuring that users receive real-time updates and notifications in the event of an emergency. The intuitive user interface, characterized by a clear display and user-friendly controls, simplifies the operation process, making it easier for staff to manage the fire alarm system effectively.

Additionally, the Tyco F3200 is compatible with various detection devices, including smoke detectors, heat detectors, and manual pull stations. This compatibility means that the system can be tailored to meet specific safety needs, accommodating a wide array of environments. Furthermore, the panel supports both conventional and addressable devices, providing flexibility in system design.

Another significant advantage of the Tyco F3200 is its advanced communication capabilities. The panel can integrate with various alarm transmission technologies, including RS-232 and RS-485 interfaces, allowing for seamless communication with remote monitoring stations. This feature enhances the reliability of emergency response efforts.

Moreover, the F3200 includes robust diagnostic and reporting tools that help maintenance personnel ensure the system's optimal performance. It provides comprehensive event logs and troubleshooting features, allowing for easy identification of issues and efficient maintenance procedures.

In summary, the Tyco F3200 is an advanced fire alarm control panel that integrates cutting-edge technology, flexibility, and user-friendliness. Its modular design, quick response time, compatibility with various devices, and strong communication capabilities make it an excellent choice for anyone seeking a dependable fire alarm system. Whether for small businesses or large-scale operations, the F3200 delivers essential fire safety solutions tailored to meet the diverse needs of its users.