Note: You can also lock or unlock a system by press- ing Func , selecting the system, then pressing Func + L/O.
Setting the System Hold Time
Menu
Program System
Select the system
Edit Sys Option
Set Hold Time
This setting controls how many seconds the scanner scans a system before moving to the next unlocked system. Enter a value from
Notes:
•If you select 0, the scanner stays on the system for a minimal time (only long enough to check cur- rent system activity).
•The default setting is 2 seconds for each system.
•For conventional systems, all unlocked channels will be scanned at least once regardless of this setting.
•The scanner moves to the next system after the hold time expires, any current transmission ends, and the channel delay time expires.
Setting the Channel Delay Time
Menu
Program System
Select the system
Edit Sys Option
Set Delay Time
This setting controls how many seconds the scanner waits after a transmission ends before resuming scanning. Enter a value from
Programming/Editing Optional Settings
74