Introduction
16975-0131-01-01
Removable Components
The wiring box is standard for all North American models of the GT Inverter.
Some European models ar e available without the w iring box. See Model
Configurations on page18 f or specific details. The heat sink cover and fan
assembly are available in the optional Fan Kit.

Wiring Box (standard on North American models)

The wiring box provides a location for making AC, DC and ground connections.
It also contains the combined AC/DC (Utility/PV array) Disconnect Switch.
The GT Inverter unit may be easil y r emoved from the wiring box in the event that
the inverter requires servicing.
Important:
In North America and other locations the wiring box is an electrical code
requirement. It must be attached during operation. Check with your local authorities
before removing the GT Inverter wiring box.
Figure 1-4
Wiring Box for the GT Inverter
1.9 cm (3/4”) Threaded
Conduit holes
DC Connect holes Control Board
Connect hole
AC Connect hole
AC/DC Disconnect
Switch
Wiring Box
Front Cover