Installing Accessories

Mounting Multiple Inverters in Parallel

As shown in Figure 2-10, inverters can be mounted side by side on wallboard or a plywood support. A minimum of 30 cm (12 inches) of clearance between the units is recommended.

Conduit nipples should be installed on one side of the first inverter before mounting on the bracket. Ensure that the sealing ring is located on the conduit nipple between inverters, i.e., on the outside of the wiring box. The lock nut is attached after the nipple is inserted into the conduit hole of the second inverter

Installing Accessories

The optional fan assembly and heat sink cover (see Figure 1-5 on page 1–7) should be installed together. Neither accessory should be installed without the other.

Installing the Fan Assembly

WARNING: Shock hazard

If the inverter is already installed and operational, turn OFF the breaker switches in the main utility service panel and the AC/DC Disconnect switch on the inverter wiring box before performing this procedure.

WARNING: Shock hazard

Hazardous voltages may be present when cover is removed. After disconnecting all sources of energy, wait 5 minutes before removing cover.

WARNING: Burn hazard

Ensure that the inverter and heat sink are not too hot to touch before attempting this procedure.

Important: The fan assembly should only be installed by qualified personnel.

The fan assembly (see Figure 1-5 on page 1–7) is optional for the GT Inverter.

Installing the fan assembly involves two main steps:

1.Attaching the fan assembly to the inverter.

2.Connecting the fan wires.