Installation
212 975-0131-01-01
Conduit
holes/knockouts Pre-plan the wire and conduit runs. Knockouts for 1.9 cm (3/4 inch) or 2.5 cm
(1 inch) conduit holes are located on the bottom and back of the wiring box.
Threaded 3/4 conduit holes are loc ated on each side of the wiring box
(Figure 2-5).
For maximum safety, run AC, DC, and communication wires in separate conduits.
Planning AC Wire Routing
AC connections include all the wires and connectors between the GT Inverter AC
terminals and the main utility service panel. Pre-plan these routes carefully before
installing the components.
Planning DC Wire Routing
DC connections include all the wires and connectors between your PV array and
the DC terminals of the GT Inverter. Pre-plan these routes care fully before
installing the components.
Figure 2-5
Knockout Locations on Bottom of Wiring Box
WARNING: Shock hazard
Check for existing electrical or plumbing prior to drilling holes in the walls.
1.9 cm (3/4) or 2.5 cm (1) Knockouts,
also on back of Wiring Box
AC/DC Disconnect Switch
Front of Wiring Box
Left side Right side
Back of Wiring B ox
1.9 cm (3/4) Threaded
Conduit Holes