Mounting the Inverter
WARNING: Shock hazard
Before drilling holes to mount the GT Inverter, ensure there are no electrical wires or plumbing in this area.
WARNING: Personal injury
The GT Inverter weighs approximately 20 kg (45 lbs). Always use proper lifting techniques during installation to prevent personal injury.
WARNING: Explosion hazard
Do not store combustible or flammable materials anywhere near the inverter.
Surfaces for Mounting
| 
 | The GT Inverter weighs approximately 20 kg (45 lbs). The supporting surface | 
| 
 | must be strong enough to handle 75 kg (160 lb). If the supporting surface is not | 
| 
 | strong enough to handle that weight, then supporting material such as a sheet of | 
| 
 | plywood can be used to enhance the strength of the mounting surface. | 
| 
 | The GT Inverter can be mounted to a vertical surface such as wallboard, wood | 
| 
 | siding, concrete wall or pole assembly. | 
| Mounting on poles | • See “Mounting on Poles or Rails” on page  | 
| or rails | is a minimum of 100 cm (39 inches) from the ground if mounted outdoors. | 
| Mounting to | • Installation onto wallboard requires either the use of a supporting material | 
| wallboard with | such as plywood or securing the mounting screws to supporting wall studs. | 
| support | Use at least two screws and anchors to secure the unit to the supporting | 
| 
 | material. | 
| Mounting to siding | • If mounting to exterior siding using a wall stud for support, the plywood | 
| using wall studs | backing will not be needed. Use at least two lag screws to secure the unit to | 
| 
 | the supporting material. Ensure the screws enter the stud at least 4 cm | 
| 
 | (1.5 inches) to adequately support the weight of the unit. See “Mounting on | 
| 
 | Wallboard, Siding or Concrete” on page  | 
| Mounting to | • If mounting the unit on a concrete surface using anchors with no supporting | 
| concrete surface | material, use four screws and anchors, instead of two, to adequately secure the | 
| 
 | unit and distribute the weight. | 
| 
 | 
 | 
| 
 | Important: Local codes may impose additional mounting requirements in earthquake | 
| 
 | or other  | 
| 
 | 
 | 
| 
 | Important: Other than the mounting bracket, no mounting hardware is supplied with | 
| 
 | the GT Inverter. | 
| 
 | 
 | 