Specifications

Electrical Specifications

Input

Input voltage, Maximum Power Point range

195 to 550 Vdc

 

 

 

 

 

 

 

 

Absolute maximum array open circuit voltage

600 Vdc

 

 

 

 

 

 

 

 

Maximum input current

16.6 A DC

 

 

 

 

 

 

 

 

Maximum array short circuit current

19 A DC

 

 

 

 

 

 

 

 

Recommended PV array power

Up to 3300 W

 

 

 

 

 

 

 

 

Reverse polarity protection

Short circuit diode

 

 

 

 

 

 

 

 

Ground fault protection

GF detection, IDIF > 1 A

 

 

 

Output

 

 

 

 

 

GT3.0 North American

 

 

GT3.0 European

 

 

 

 

 

 

 

 

Maximum output power

3000 W AC

 

 

3000 W AC

 

 

 

 

 

Nominal output power over rated temp range

2500 W AC

 

 

2500 W AC

 

 

 

 

 

Maximum utility backfeed current

20 A

 

 

20 A

 

 

 

 

 

Nominal output voltage

240 V

 

 

230 V

 

 

 

 

 

Operating range, utility voltage (default)*

211 to 264 Vac

 

 

202 to 253 Vac

 

 

 

 

 

Nominal output frequency

60 Hz

 

 

50 Hz

 

 

 

 

 

Operating range, utility frequency (default)*

59.3 to 60.5 Hz

 

 

47.1 to 50.9 Hz

 

 

 

 

 

Maximum continuous output current

14.2 A

 

 

14.9 A

 

 

 

 

 

Output overcurrent protection

20 A RMS

 

 

20 A RMS

 

 

 

 

Total Harmonic Distortion (THD)

<5%

 

 

<5%

 

 

 

 

Power factor

>0.9

 

 

>0.9

 

 

 

 

 

Utility monitoring—islanding protection

Vac, fac as per UL1741

 

 

 

 

 

 

 

Output characteristics

 

Current source

 

 

 

 

Output current waveform

 

 

Sine wave

 

 

 

 

 

*Requires Utility permission and qualified service personnel to change settings.

A–2

975-0131-01-01

Page 96
Image 96
Xantrex Technology owner manual Electrical Specifications, Input, Output, GT3.0 European