Installation

Mounting on Poles or Rails

To mount the unit using poles:

1.Ensure that poles or rails are securely assembled in place. If using horizontal rails, three rails are required: two for the mounting bracket and a third for securing the bottom edge of the inverter wiring box (see Figure 2-9).

2.Connect the mounting bracket vertically to the poles or rails (Figure 2-9):

Be sure to use at least two bolts to secure the mounting bracket to the support.

Position the lower edge of the bracket a minimum of 110 cm (43 inches) above the floor or ground.

3.If using a single vertical pole, ensure that the inverter is secure and unable to rotate around the pole.

110 cm (43”)

Ground /

Floor

Mounting Bracket

At least 2 bolts to

48 cm

secure bracket to

(18.9”)

poles/rails.

 

 

15 cm

 

(5.9”)

For securing

the bottom of

100 cm

the wiring box

(39”)

Ground /

Floor

Figure 2-9Examples of Mounting on a Pole or Rails

2–20

975-0131-01-01

Page 48
Image 48
Xantrex Technology GT3.0 owner manual Mounting on Poles or Rails, To mount the unit using poles, Ground Floor