Xanbus Network Installation

The total length of the network, including all connected Xanbus-enabled devices and the XW Series, cannot exceed 130 feet (40 m). See Table 3-3.

Table 3-3Minimum and Maximum Cable Length

Cable Length

Minimum

Maximum

 

 

 

Backbone or daisy chain

4 inches (10 cm)

130 feet (40 meters)

Total backbone length or daisy chain

4 inches (10 cm)

130 feet (40 meters)

Drop cable on backbone

4 inches (10 cm)

10 feet (3 meters)

 

 

 

Mounting a Network Connector

To mount a network connector:

1.Select an appropriate location with the connector in the recommended mounting orientation, as shown in Figure 3-7.

Figure 3-7Recommended Mounting Orientation for Network Connector

2.Mark the position of the mounting screws.

3.Pilot drill the two mounting holes.

4.Fasten the network connector to the mounting surface with two #6 screws.

3–8

975-0239-01-01

Page 74
Image 74
Xantrex Technology XW4024-120/240-60, XW4548-120/240-60, XW6048-120/240-60 manual Mounting a Network Connector