XW System Accessories Installation

Tabs in vertical position

Figure 5-2Inserting the Mounting Plate

4.Secure the mounting plate by tightening the two screws to rotate the tabs to the horizontal position (see Figure 5-3) and pull the tabs tight against the inner surface of the wall. Be careful not to overtighten the screws and damage the wall.

Rotate tabs to horizontal position

Figure 5-3Securing the Mounting Plate

5.Connect the network cable(s) (and terminator if necessary) to either input on the back of the XW System Control Panel. See Figure 5-4.

Connect a network terminator to the XW System Control Panel if it is the last device at the end of a series-type network layout.

Important: To ensure communication signal quality, the network must be terminated at each end with a terminator.

5–4

975-0239-01-01