Mounting

Removing the Wiring Terminals Cover

Before mounting, you must remove the wiring terminals cover to access the mounting holes and the wiring terminals. The wiring terminals cover is secured with two Phillips #8-32 × 2 ½-inch screws on the front cover of the unit. See Figure 4-2.

xantrex

Remove screws to access the field-wiring terminals.

Figure 4-2Removing the Wiring Terminals Cover

Removing Knockouts

Six dual and two single knockouts are provided for routing battery, PV array, BTS, and network cables into the XW Solar Charge Controller. Bushings or conduits must be used to protect the wiring from damage from rough edges around the knockout holes.

Side screws for power distributionKeyhole slot for wall mounting

panel mounting

2 7/8"

(73 mm)

 

 

12 ¾"

11"

 

(323 mm)

 

 

(280 mm)

14 ½"

 

 

 

 

(368 mm)

Additional

 

 

 

 

mounting holes

 

¼"

 

 

(6.35 mm)

 

2 3/8"

 

2 1/16"

(60 mm)

 

 

(53 mm)

 

 

1"

9/16"

4 5/8"

(25.4 mm)

(118 mm)

 

(14 mm)

5 ¾"

5 7/16"

 

 

(146 mm)

(138 mm)

 

 

 

Figure 4-3Dimensions and Knockout Locations

975-0239-01-01

4–5

Page 81
Image 81
Xantrex Technology XW4024-120/240-60, XW4548-120/240-60, XW6048-120/240-60 manual Removing the Wiring Terminals Cover