4.3 SNMP Traps
The switch supports the following SNMP traps. When the trap event occurs, the SNMP agent will generate a trap notification to SNMP trap manager stations. Up to three trap managers can be supported. Each trap manager must be configured with : IP address and Community string which the trap manager belongs.
The provided traps and associated events are:
Trap Name | RFC1157 | Event of Trap Generated | |
Cold Start | Generic | The device is powered on or | reboot |
|
| remotely and complete initialization | |
Authentication | Generic | SNMP community authentication failure | |
Port link change | Generic | Any switched port link down | |
Port link change | Generic | Any switched port link recovery | |
Fan 1 failure | Specific | Fan 1 failure warning or recovery | |
Fan 2 failure | Specific | Fan 2 failure warning or recovery |