Optimizing the speaker setting for your listening room

Parameter

Descriptions

 

 

Distance

This unit checks and adjusts the distance of

(Speaker distance)

each speaker from the listening position and

 

adjusts the timing of each channel.

 

 

Size

This unit checks and adjusts the frequency

(Speaker size)

response of each speaker and sets the

 

appropriate low-frequency crossover for

 

each channel.

 

 

Equalizing

Parametric equalizer adjusts the level of the

(Speaker

specified frequency bands. This unit

equalizing)

automatically selects the crucial frequency

 

bands for the listening room and adjusts the

 

level of the selected frequency bands to

 

create a cohesive sound field in the room.

 

 

Level

This unit checks and adjusts the volume

(Speaker level)

level of each speaker.

 

 

Retry

Exit Detail

Pre Check

E09:User Cancel

Main Check

Wiring

7Press 9ENTER to exit from the “Result” screen.

y

To view the measurement results in detail, press 9h. Press 9k / n repeatedly to toggle between parameters (page 35). Press 9l to return to the “Result” screen.

To retry the measurement from step 4, press 9k.

5If you have finished the settings, press 9l

to return to the previous menu level and then press 9n to select “Start”.

Before proceeding next operation

Once you perform the next operation, this unit starts the automatic setup procedure in 10 seconds. During the automatic setup procedure, do not perform any operation on this unit. For more accurate measurements, we recommended that you get out of the room or move to the wall where speakers are not around during the measurement. It takes approximately 3 minutes.

6Press 9ENTER to start the measurement.

This unit starts to count down from 10 seconds. y

To start the measurement immediately, press 9ENTER again.

To cancel the automatic setup and return to the previous screen, press 0RETURN.

Loud test tones are output from each speaker during the measurement. Once all items are measured, “Measurement Completed Successful” appears.

 

 

 

 

 

Equalizing

 

 

 

Level

Measurement Completed

 

 

Sucessful

 

 

 

 

 

Result

 

 

 

 

Detail:[ ]

 

 

 

Exit:ENTER

 

 

 

 

 

 

 

 

 

Note

If an error or warning message appears, see “Error and warning messages” (page 32).

8Press 9l to save the measurement results or 9h to discard them.

9Press IMENU to turn off the GUI menu and disconnect the optimizer microphone.

Error and warning messages

If an error or warning message appears during the automatic setup procedure, carry out one of the following operations. For details on each message, see “Automatic setup” (page 113).

To view the details on the error and warning messages, press 9h. Press 9k / n to display the previous/next page (if available). Press 9lto return to the previous menu level.

To return to the GUI menu, press 9l.

To retry the measurement, press 9k.

To ignore the message and continue the process, press

9n.

Note

Some operations cannot be performed depending on the type of error (or warning).

32 En