Advanced automatic setup

Use this feature to optimize the setup of this unit for multiple listening positions. You can also select the parameters to be optimized by the automatic setup.

1Turn on the video monitor and then connect the optimizer microphone to the OPTIMIZER MIC jack on the front panel.

2Place the optimizer microphone at the first listening position.

The following illustration shows how to place the optimizer microphone in order to optimize the setup of this unit for seven listening positions for example.

17

26 3 4 5

1/2/3/4/5/6/7: Listening positions

3Press IMENU on the remote control.

The GUI menu appears in the video monitor.

4Press 9k to select “Setup Menu” and then press 9h.

5Press 9k / n repeatedly to select “Multi Measure” and then press 9h.

Information

Setup Menu

Multi Measure 1

StartWiring

Distance

Optimizing the speaker setting for your listening room

6Press 9k / n repeatedly to set the number of listening positions and press 9l.

Choices: 1 (default), 2, 3, 4, 5, 6, 7, 8

Information

Setup Menu

Multi Measure 7

StartWiring

Distance

7To select the parameters to be optimized,

press 9k / n to select the parameter and then press 9ENTER to check or uncheck

the box.

When you do not need to select the parameters to be optimized, skip to step 8.

y

If you do not select the parameters to be optimized, this unit will optimize the parameters you selected last time. All the parameters are selected by the initial factory settings.

8Press 9l to return to the previous menu level and then press 9n to select “Start”.

Before proceeding next operation

Once you perform the next operation, this unit starts the automatic setup procedure in 10 seconds. During the automatic setup procedure, do not perform any operation on this unit. For more accurate measurements, we recommended that you get out of the room or move to the wall where speakers are not around during the measurement.

9Press 9ENTER to start the measurement.

This unit starts to count down from 10 seconds. y

To start the measurement immediately, press 9ENTER again.

To cancel the automatic setup and return to the previous screen, press 0RETURN.

Loud test tones are output from each speaker during the measurement. Once all items for the first listening position are measured, the following message appears.

PREPARATION

Pre Check

Put the microphone at

Main Check

2nd listening position

Next:ENTER

 

Wiring

Skip:[ ]

Distance

 

English

33 En