Routine Maintenance

 

143

 

Replace the Fuse

 

 

Replace the Fuse

The instructions that follow are for the 90XiIIIPlus, 96XiIIIPlus, 140XiIIIPlus, 170XiIIIPlus, R170Xi, and 220XiIIIPlus printers only. Fuses are not user-replaceable in the 110XiIIIPlus and R110Xi.

Caution • Turn the AC power switch off (O) and remove the power cord before performing this procedure.

The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is provided as a spare. The end caps of the fuse must bear the certification mark of a known international safety organization (see Figure 6 on page 34).

To replace a faulty fuse, complete these steps:1.Use a small-blade screwdriver or similar tool to remove the fuse holder.

The fuse holder is part of the AC power entry module at the rear of the printer (Figure 29).

Figure 29 • AC Power Entry Module

1

2

3

4

1Power switch2Fuse holder3AC power entry module4Small-blade screwdriver

2.Remove the faulty fuse and install a new fuse in the in-circuit position (Figure 30). Important • If you use the spare fuse, be sure to order a replacement fuse from an

authorized Zebra distributor. The spare fuse should be the exact type and rating as the original in-circuit fuse.

9/6/07

XiIIIPlus/R110Xi/R170Xi User Guide

13383L-004 Rev. A