Data Ports

 

185

 

 

 

 

 

 

 

Applicator Interface Connector

 

 

 

Table 22 • Applicator Interface Connector Pin Configuration (Continued)

 

 

 

 

 

 

 

 

 

Pin

Signal Name

Signal Type

Description

 

 

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

END PRINT

Output

See Applicator Signals on page 181 for more information

 

 

 

 

 

 

about the start and end print signals. See Set Applicator

 

 

 

 

 

Port Mode on page 95 for more information about the

 

 

 

 

 

modes.

 

 

 

 

 

MODE 0—The applicator port is OFF.

 

 

 

 

 

MODE 1—Asserted LOW only while the printer is

 

 

 

 

 

moving the label forward; otherwise deasserted HIGH.

 

 

 

 

 

MODE 2—Asserted HIGH only while the printer is

 

 

 

 

 

moving the label forward; otherwise deasserted LOW.

 

 

 

 

 

MODE 3—(Default) Asserted LOW for 20

 

 

 

 

 

milliseconds when a label is completed and positioned.

 

 

 

 

 

Not asserted during continuous printing.

 

 

 

 

 

MODE 4—Asserted HIGH for 20 milliseconds when a

 

 

 

 

 

label is completed and positioned. Not asserted during

 

 

 

 

 

continuous printing.

 

 

 

 

 

 

 

 

 

12

MEDIA OUT

Output

Asserted LOW while there is no media in the printer.

 

 

 

 

 

 

 

 

 

13

RIBBON OUT

Output

Asserted LOW while there is no ribbon in the printer.

 

 

 

 

 

 

 

 

 

14

DATA READY

Output

See Applicator Signals on page 181 for more information

 

 

 

 

 

about this signal.

 

 

 

 

 

• Asserted LOW when sufficient data has been received

 

 

 

 

 

to begin printing the next label.

 

 

 

 

 

• Deasserted HIGH whenever printing stops after the

 

 

 

 

 

current label, due to either a pause condition or the

 

 

 

 

 

absence of a label format.

 

 

 

 

 

 

 

 

 

15

SPARE

Output

To be determined.

 

 

(Non-

 

 

 

 

 

 

RFID)

 

 

 

 

 

 

 

 

 

 

 

 

 

15

VOID

Output

• Asserted LOW when the RFID transponder over the

 

 

(RFID)

 

 

antenna is “voided.”

 

 

 

 

 

• Deasserted HIGH when the end print signal is asserted.

 

 

 

 

 

 

 

 

 

* Applicator boards have separate part numbers for the +5V version (49872-099M) and the +24-28V version (33361-099M).

9/6/07

XiIIIPlus/R110Xi/R170Xi User Guide

13383L-004 Rev. A