186Data Ports

Applicator Interface Connector

Jumper Configurations and Pinouts for +5 V I/O Operation

Jumpers JP1 and JP2 are used together to produce isolated or non-isolated modes of operation for applicator input and output control signals. JP1 configures the +5 V source for the optoisolator circuits, and JP2 configures the ground. For proper operation, when JP1 is installed, JP2 must be installed, and when JP1 is removed, JP2 must be removed.

Table 23 describes the pin and jumper configurations for +5 V I/O operation.

Table 23 • Non-Isolated and Isolated Modes for +5V Operation

 

Non-Isolated (Jumpers In)

 

Isolated (Jumpers Out)

 

Pin 1

Ground +5V, Jumper JP2 In

 

 

External Ground +5V, Jumper JP2 Out

 

I/O ground is connected to the printer signal

I/O ground is disconnected from the printer

 

ground.

 

 

 

signal ground. Ground must be provided

 

 

 

 

 

externally to this pin.

 

 

Pin 2

+5V Output, Jumper JP1 In

 

 

External +5V Input, Jumper JP1 Out

 

+5 V I/O is connected to the applicator

+5 V I/O is disconnected from the applicator

 

interface circuit +5 V Supply.

 

 

interface circuit +5 V Supply. The +5 V for the

 

 

 

 

 

applicator interface optoisolator circuits must be

 

 

 

 

 

provided externally. This input also supplies

 

 

 

 

 

voltage for output signal pull-up resistors.

Pinouts

 

 

 

 

 

 

 

 

 

 

JP2

 

 

 

JP2

 

 

 

+5V

 

 

 

+5V

 

 

 

 

1A

JP1

1

 

1A

JP1

1

 

 

 

 

 

 

 

 

+5V

+5V

 

+5V

+5V

 

 

2

 

2

 

 

 

3

 

 

 

3

 

 

 

 

4

 

 

 

4

 

 

 

 

5

 

 

 

5

 

 

 

+28V

6

+28V

 

+28V

6

+28V

 

 

2A

7

 

2A

7

 

 

8

 

 

8

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

9

 

 

 

 

10

 

 

 

10

 

 

 

 

11

 

 

 

11

 

 

 

 

12

 

 

 

12

 

 

 

 

13

 

 

 

13

 

 

 

 

14

 

 

 

14

 

 

 

 

15

 

 

 

15

 

13383L-004 Rev. A

XiIIIPlus/R110Xi/R170Xi User Guide