Configuration

 

95

 

 

 

 

 

 

 

 

 

 

 

Control Panel Parameters

 

 

 

 

 

Table 10 • Printer Parameters (Sheet 24 of 27)

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

Action/Explanation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Applicator Port Mode

 

 

 

 

APPLICATOR PORT

 

 

 

 

 

 

+

 

Determines the action of the applicator port.

 

 

 

-

OFF

 

Note • Set this value as suggested by the applicator manufacturer.

 

 

 

 

 

 

 

Default: OFF

 

 

 

 

 

 

 

Selections: OFF, MODE 1, MODE 2, MODE 3, MODE 4

 

 

 

 

 

 

 

OFF: The applicator port is off.

 

 

 

 

 

 

 

MODE 1: Asserts the ~END_PRINT signal low while the printer is

 

 

 

 

 

 

 

moving the label forward.

 

 

 

 

 

 

 

MODE 2: Asserts the ~END_PRINT signal high while the printer is

 

 

 

 

 

 

 

moving the label forward.

 

 

 

 

 

 

 

MODE 3: Asserts the ~END_PRINT signal low for 20 milliseconds

 

 

 

 

 

 

 

when a label has been completed and positioned. Not asserted during

 

 

 

 

 

 

 

continuous printing modes.

 

 

 

 

 

 

 

MODE 4: Asserts the ~END_PRINT signal high for 20 milliseconds

 

 

 

 

 

 

 

when a label has been completed and positioned. Not asserted during

 

 

 

 

 

 

 

continuous printing modes.

 

 

 

 

 

 

 

To change the value shown:

 

 

 

 

 

 

 

1. Press the left or right oval to scroll through the options.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select Start Print Signal

 

 

 

START PRINT SIG

 

 

 

 

 

 

 

This parameter determines how the printer reacts to the Start Print Signal

 

 

 

- PULSE MODE

+

 

input on pin 3 of the applicator interface connector at the rear of the printer.

 

 

 

 

 

 

 

Caution • Start Print Signal is set by the applicator manufacturer and

 

 

 

 

 

 

 

should not be changed unless the factory defaults have been reloaded.

 

 

 

 

 

 

 

Please make a note of it. While other choices are valid, the printer must

 

 

 

 

 

 

 

be returned to its designated setting for it to work properly.

 

 

 

 

 

 

 

Default: PULSE MODE

 

 

 

 

 

 

 

Selections: PULSE MODE, LEVEL MODE

 

 

 

 

 

 

 

PULSE MODE—Labels print when the signal transitions from

 

 

 

 

 

 

 

HIGH to LOW.

 

 

 

 

 

 

 

LEVEL MODE—Labels print as long as the signal is asserted LOW.

 

 

 

 

 

 

 

To change the value shown:

 

 

 

 

 

 

 

1. Press the left or right oval to toggle between the options.

 

 

 

 

 

 

 

 

 

 

 

9/6/07

XiIIIPlus/R110Xi/R170Xi User Guide

13383L-004 Rev. A