184Data Ports

Applicator Interface Connector

Table 22 • Applicator Interface Connector Pin Configuration (Continued)

Pin

Signal Name

Signal Type

Description

No.

 

 

 

 

 

 

 

5

PAUSE

Input

To toggle the current Pause state, this input must be

 

 

 

asserted LOW for 200 milliseconds, or until the

 

 

 

SERVICE REQUIRED output (pin 10) changes state.

 

 

 

 

6

REPRINT

Input

• If the Reprint feature is enabled, this input must be

 

 

 

asserted LOW to cause the printer to reprint the last

 

 

 

label.

 

 

 

• If the Reprint feature is disabled, this input is ignored.

 

 

 

 

7

+28 V

Power

The Interface Power Supply. Supplies power to external

 

(For the 5V board,

 

sensors as required.

 

+28V is fused at 2 A.

 

Note • If operating with 28V signals only, pin 7

 

For the 24–28V

 

may be used to supply power to pin 2, which

 

board, +28V is fused

 

creates a non-isolated mode of operation. (This is

 

at 500 mA.)

 

applicable for all printers except the

 

Caution • Replace

 

110XiIIIPlus.)

 

the fuse only with

 

 

 

one of the same

 

 

 

type and rating.

 

 

 

 

 

 

8

POWER GROUND

Ground

The Interface Power Ground.

 

(+28 V DC Return)

 

Note • If pin 7 is used to supply power to pin 2,

 

 

 

use this pin to ground pin 1. (This is applicable for

 

 

 

all printers except the 110XiIIIPlus.)

 

 

 

 

9

No function.

 

 

 

 

10

SERVICEOutputAsserted LOW in the following circumstances:

 

REQUIRED

 

• the printhead is open

 

 

 

• the ribbon or media is out

 

 

 

• the printer is paused

 

 

 

• an operational fault occurs

 

 

 

• a Resynch error occurs while the applicator Resynch

 

 

 

mode is set to Error mode (see Select Resynch Mode

 

 

 

on page 96)

 

 

 

 

* Applicator boards have separate part numbers for the +5V version (49872-099M) and the +24-28V version (33361-099M).

13383L-004 Rev. A

XiIIIPlus/R110Xi/R170Xi User Guide

9/6/07