110Routine Maintenance
Cleaning Schedule and Procedures
Cleaning Schedule and Procedures
Routine preventive maintenance is a crucial part of normal printer operation. By taking good care of your printer, you can minimize the potential problems that you might have with it and help to achieve and to maintain your standards for print quality.
Over time, the movement of media or ribbon across the printhead wears through the protective ceramic coating, exposing and eventually damaging the print elements (dots). To avoid abrasion:
•Clean the printhead frequently.
•Minimize printhead pressure and burn temperature (darkness) settings by optimizing the balance between the two.
•When using Thermal Transfer mode, ensure that the ribbon is as wide or wider than the media to prevent exposing the printhead elements to the more abrasive label material.
Important • Zebra is not responsible for damage caused by the use of cleaning fluids on this printer.
Specific cleaning procedures are provided on the following pages. Table 13 shows the recommended cleaning schedule. These intervals are intended as guidelines only. You may have to clean more often, depending upon your application and media.
|
|
| . | |
| Table 13 • Recommended Cleaning Schedule | |||
|
|
|
| |
Area |
| Method | Interval | |
|
|
|
| |
Printhead |
| Solvent* | Direct Thermal Mode: After every roll of | |
|
|
| media (or 500 feet of fanfold media). | |
Platen roller |
| Solvent* | ||
| Thermal Transfer Mode: After every roll of | |||
|
|
| ||
Media sensors | Air blow | |||
ribbon. | ||||
|
|
| ||
Ribbon sensor | Air blow |
| ||
|
|
|
| |
Media path |
| Solvent* |
| |
|
|
|
| |
Ribbon path |
| Solvent* |
| |
|
|
| ||
Pinch roller (part of | Solvent* |
| ||
|
|
|
| |
Cutter | If cutting continuous, | Solvent* | After every roll of media (or more often, | |
module |
| depending upon your application and media). | ||
|
|
|
| |
| If cutting tag stock or label | Solvent* and | After every two or three rolls of media. | |
| liner material | air blow |
| |
|
|
|
| |
Solvent* | Once a month. | |||
|
|
| ||
Air blow | Once every six months. | |||
|
|
|
|
*Zebra recommends using Preventive Maintenance Kit (part number 47362). In place of this kit, you may use a clean swab dipped in a solution of isopropyl alcohol (minimum 90%) and deionized water (maximum 10%).
8/22/12 |