Chapter 8 Basic Setting

Click the PoE Setup link in the Basic Setting > PoE Status screen. The following screen opens.

Figure 46 Basic Setting > PoE Setup

The following table describes the labels in this screen.

Table 15 Basic Setting > PoE Setup

LABEL

DESCRIPTION

PoE Mode

Select the power management mode you want the Switch to use.

 

Classification - Select this if you want the Switch to reserve the Max

 

Power (mW) to each PD according to the priority level. If the total

 

power supply runs out, PDs with lower priority do not get power to

 

function.

 

Consumption - Select this if you want the Switch to manage the total

 

power supply so that each connected PD gets a resource. However, the

 

power allocated by the Switch may be less than the Max Power (mW) of

 

the PD. PDs with higher priority also get more power than those with

 

lower priority levels.

 

 

Port

This is the port index number.

 

 

PD

Select this to provide power to a PD connected to the port.

 

If left unchecked, the PD connected to the port cannot receive power from

 

the Switch.

 

 

88

 

GS2200-24 User’s Guide