| Chapter 8 Basic Setting |
|
|
|
| Table 10 Basic Setting > System Info (continued) | |
| LABEL | DESCRIPTION |
| Ethernet | This field refers to the Ethernet MAC (Media Access Control) address of the |
| Address | Switch. |
|
|
|
| Hardware Monitor | |
|
|
|
| Temperature | The Switch has temperature sensors that are capable of detecting and |
| Unit | reporting if the temperature rises above the threshold. You may choose |
|
| the temperature unit (Centigrade or Fahrenheit) in this field. |
|
|
|
| Temperature | BOARD, PHY, and MAC refer to the location of the temperature sensors |
|
| on the Switch printed circuit board. |
|
|
|
| Current | This shows the current temperature at this sensor. |
|
|
|
| MAX | This field displays the maximum temperature measured at this sensor. |
|
|
|
| MIN | This field displays the minimum temperature measured at this sensor. |
|
|
|
| Threshold | This field displays the upper temperature limit at this sensor. |
|
|
|
| Status | This field displays Normal for temperatures below the threshold and Error |
|
| for those above. |
|
|
|
| Fan Speed | A properly functioning fan is an essential component (along with a |
| (RPM) | sufficiently ventilated, cool operating environment) in order for the device |
|
| to stay within the temperature threshold. Each fan has a sensor that is |
|
| capable of detecting and reporting if the fan speed falls below the |
|
| threshold shown. |
|
|
|
| Current | This field displays this fan's current speed in Revolutions Per Minute (RPM). |
|
|
|
| MAX | This field displays this fan's maximum speed measured in RPM. |
|
|
|
| MIN | This field displays this fan's minimum speed measured in RPM. “<41" is |
|
| displayed for speeds too small to measure (under 2000 RPM). |
|
|
|
| Threshold | This field displays the minimum speed at which a normal fan should work. |
|
|
|
| Status | Normal indicates that this fan is functioning above the minimum speed. |
|
| Error indicates that this fan is functioning below the minimum speed. |
|
|
|
| Voltage (V) | The power supply for each voltage has a sensor that is capable of |
|
| detecting and reporting if the voltage falls out of the tolerance range. |
|
|
|
| Current | This is the current voltage reading. |
|
|
|
| MAX | This field displays the maximum voltage measured at this point. |
|
|
|
| MIN | This field displays the minimum voltage measured at this point. |
|
|
|
| Threshold | This field displays the percentage tolerance of the voltage with which the |
|
| Switch still works. |
|
|
|
| Status | Normal indicates that the voltage is within an acceptable operating range |
|
| at this point; otherwise Error is displayed. |
|
|
|
| 107 |
|
|