Teledyne 10 manual Pump assembly components

Page 54

BioOptix™ 10

Section 4 System Maintenance

Piston Plug

Top O-Ring (P/N 202-5001-09)

Glass Cylinder

Seal (P/N 202-9090-32)

Push Rod

Bottom O-Ring (P/N 202-5001-09)

Wrench Slots

.375 OD Flat Washer

.5 OD Rubber Washer

.5 OD Flat Washer

#6 Interior Lock Washer

#6 1/4" Pan Head Screw

Retainer Plate

Figure 4-3 Pump assembly components

Figure 4-4 Attach seal to push rod

10-32 3/8" Pan Head Screw

#10 Interior Lock Washer

#10 Flat Washer

Inductor

#8-32 1-1/4" Pan Head Screw

Top Mounting Tab

Bottom Mounting Tab

#6 Interior Lock Washer #6 1/4" Pan Head Screw

Push Rod

Seal (P/N 202-9090-32)

4-4

Image 54
Contents BioOptix Page Foreword Page General Warnings Application, take heed in the following general warningsDamage Hazard Symbols Symboles de sécuritéBioOptix 10 Safety Table of Contents BioOptixAppendix C Replacement Parts Lists System MaintenanceAppendix B Fluid Path Diagrams Appendix a Method TemplatesList of Figures List of Tables Introduction Product OverviewBioOptix 10 Specifications Maximum Altitude 2000 metersSystem Controls and Connectors BioOptix 10 Front Panel ControlsBioOptix 10 Front Panel Controls BioOptix 10 Left-side Connections BioOptix 10 Left-side Controls and ConnectionsBioOptix 10 Right-side Connections BioOptix 10 Right-side ConnectionsBioOptix 10 Rear Panel Controls and Connections BioOptix 10 Rear Panel Controls and ConnectionsUnpacking the BioOptix 10 System InstallationBioOptix 10 Installation SpaceElectrical AssemblingBioOptix Accessing pump and column module internal connections Routing the Sample Out lines column module P110 Connection on BD3 AC power connection from pump module 10 Liquid connections pump module shown 11 Aligning the fasteners Ceeding with the arm assembly instructions FoxyBioOptix Installation Common Buffer Inlet Mounting Block Manifold Tubing Color chart Channel Numbers Color Part Number16 Foxy 200 tubing connections Configuring Windows PC Minimum RequirementsBioOptix 10 Software BioOptix 10 System Preparation 18 Column bypass tubing 20 BioOptix 10 Manual Hardware Control window BioOptix Installation Sample Preparation Column Installation OperationAdapters BioOptix 10 Software GradientsOverview Methods Defining a Gradient To define a gradientEquilibrate tab settings Load Settings This block loads the sample onto the column Load tab settingsWash Settings Flush Settings ExperimentsSetting up Operation Buttons RunningExperiment FileZoom and pan OperationPost-experiment Operation Pump FlushSaving Run Data PreviewAutoReports BioOptix 10 Operation System Maintenance Vent damageExterior Cleaning Piston Seal Replacement Refer to -3 for the following steps Pump assembly components Deuterium Lamp Replacement Waste port mounting plate Troubleshooting Common ProblemsOperating Problems Inaccessible Fuses Circuit breaker location Service Department How to Ship ReturnsTeledyne Isco, Inc Appendix a Method Templates Dard.tpl Modifying Template General Editing RulesBlocks BlocknOther Appendix B Fluid Path Diagrams Fluid-type BlocksBioOptix Appendix B Fluid Path Diagrams Load-type BlocksFigure B-4 Fluid path for Load-type blocks Manual injections Plumbing Diagram Pump FlushFigure B-7 BioOptix 10 Plumbing Diagram BioOptix Appendix B Fluid Path Diagrams Appendix C Replacement Parts Lists BioOptix Appendix C Replacement Parts Lists Detector Assembly 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists Column Module 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists Pump Module 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists Declaration of Conformity Page Teledyne Isco One Year Limited Factory Service Warranty