Teledyne manual Windows PC Minimum Requirements, Configuring, BioOptix 10 Software

Page 32

BioOptix™ 10

 

Section 2

Installation

 

 

 

 

2.2.6

Windows PC

The Windows® personal computer (PC) must meet the following

 

Connection

minimum requirements:

Table 2-2 Windows® PC Minimum Requirements

Processor:

Pentium, 133 MHz

 

 

RAM

32 MB

 

 

Hard Drive

20 MB available space

 

 

Operating System

Windows® 95, 98, 2000, NT, or XP

Communication Port

One available RS-232 port

 

 

CD-ROM

16

 

 

Monitor

VGA or better (640480 or higher resolution)

 

 

The PC should be set up according the manufacturer’s instruc- tions. After the PC is fully operational, place it on the workbench within 2 meters of the BioOptix 10.

Note

Greater lengths are possible with a user-supplied DB9 Serial

Extension Cable. Total length should not exceed 10 meters.

Connect the “Y” Serial Cable end labeled Computer Serial to the

RS-232 Serial Port on the PC.

2.3BioOptix 10 Software Install the BioOptix 10 Software on the Windows PC.

Installation

1.

Locate the BioOptix 10 Software CD that was shipped with

 

 

the system.

 

2.

After turning on the PC, insert the CD into the CD-ROM

 

 

drive.

 

3.

Using Windows Explorer, locate and open the file named

 

 

setup.exe on the CD-ROM drive.

 

4.

Follow the on-screen instructions to complete the software

 

 

installation.

2.3.1 Configuring

After installing the BioOptix 10 software on the PC, the software

BioOptix 10 Software

should be configured to match the hardware of the BioOptix 10

 

system. To configure the software:

 

1.

Start BioOptix 10 software.

 

 

The software installation routine placed an icon on the

 

 

desktop. Double click this icon to start. Or, you can start

 

 

the software from the Windows Start button, navigating

 

 

through Programs>BioOptix 10>BioOptix 10.

 

2.

From the BioOptix 10 menu, select Tools>Configure….

 

3.

Match the Configuration dialog box settings to the hard-

 

 

ware.

Rack – select the rack size/type that is installed on the system.

2-14

Image 32
Contents BioOptix Page Foreword Page General Warnings Application, take heed in the following general warningsDamage Hazard Symbols Symboles de sécuritéBioOptix 10 Safety Table of Contents BioOptixSystem Maintenance Appendix B Fluid Path DiagramsAppendix C Replacement Parts Lists Appendix a Method TemplatesList of Figures List of Tables Introduction Product OverviewBioOptix 10 Specifications Maximum Altitude 2000 metersBioOptix 10 Front Panel Controls System Controls and ConnectorsBioOptix 10 Front Panel Controls BioOptix 10 Left-side Connections BioOptix 10 Left-side Controls and ConnectionsBioOptix 10 Right-side Connections BioOptix 10 Right-side ConnectionsBioOptix 10 Rear Panel Controls and Connections BioOptix 10 Rear Panel Controls and ConnectionsInstallation BioOptix 10 InstallationUnpacking the BioOptix 10 System SpaceBioOptix ElectricalAssembling Accessing pump and column module internal connections Routing the Sample Out lines column module P110 Connection on BD3 AC power connection from pump module 10 Liquid connections pump module shown 11 Aligning the fasteners Ceeding with the arm assembly instructions FoxyBioOptix Installation Common Buffer Inlet Mounting Block Manifold Tubing Color chart Channel Numbers Color Part Number16 Foxy 200 tubing connections BioOptix 10 Software ConfiguringWindows PC Minimum Requirements BioOptix 10 System Preparation 18 Column bypass tubing 20 BioOptix 10 Manual Hardware Control window BioOptix Installation Adapters Sample Preparation Column InstallationOperation Overview BioOptix 10 SoftwareGradients Methods Defining a Gradient To define a gradientEquilibrate tab settings Load Settings This block loads the sample onto the column Load tab settingsWash Settings Flush Settings ExperimentsSetting up Running ExperimentOperation Buttons FileZoom and pan OperationPost-experiment Operation Pump FlushSaving Run Data PreviewAutoReports BioOptix 10 Operation System Maintenance Vent damageExterior Cleaning Piston Seal Replacement Refer to -3 for the following steps Pump assembly components Deuterium Lamp Replacement Waste port mounting plate Operating Problems TroubleshootingCommon Problems Inaccessible Fuses Circuit breaker location Teledyne Isco, Inc Service DepartmentHow to Ship Returns Appendix a Method Templates Dard.tpl Modifying Template General Editing RulesOther BlocksBlockn Appendix B Fluid Path Diagrams Fluid-type BlocksBioOptix Appendix B Fluid Path Diagrams Load-type BlocksFigure B-4 Fluid path for Load-type blocks Manual injections Plumbing Diagram Pump FlushFigure B-7 BioOptix 10 Plumbing Diagram BioOptix Appendix B Fluid Path Diagrams Appendix C Replacement Parts Lists BioOptix Appendix C Replacement Parts Lists Detector Assembly 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists Column Module 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists Pump Module 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists 13BioOptix 10 Replacement Parts Lists Declaration of Conformity Page Teledyne Isco One Year Limited Factory Service Warranty