Switch Interface Example
Switch Interface
(Sinking)
+5 to +24VDC
GND +
SPST
Switch
Optocoupler Reference
MDriveACPlus Microstepping
Enable Input
Switch Interface
(Sourcing)
+5 to +24VDC
GND +
SPST
Switch
Optocoupler Reference
MDriveACPlus Microstepping
Enablle IInputt
Figure 2.1.6: Switch Interface Example
Fault (Temperature Warning) Output
The MDriveAC Plus Microstepping features an
When the internal temperature of the MDriveAC Plus reaches the temperature specified by the WARN_TEMP parameter, the output will pulse at 1 second intervals (1/2 second on, 1/2 second off). When an
The output will remain in the latched condition until a power cycle, or new parameter set from the IMS SPI Mo- tor Interface.
|
| Fault Output |
| |
| Input Type |
| Open Drain |
|
|
|
|
|
|
|
| +5 to +24 VDC |
| |
| Drain Current |
| 50 mA |
|
|
|
|
| |
| Table 2.1.3: Fault Output Specifications | |||
| MDriveAC Plus Microstepping Hardware - Revision R121707 | |||
|
|
| Relevant to Firmware Version 3.0.02 |