Panasonic WV-CW864 operating instructions Deleting Preset Positions, Home Position Setting

Page 21

Deleting Preset Positions

1.Move the cursor to PRESET 1 and select the position number to be deleted by using the joystick.

2. Press the CAM (SET) key to display the preset setting menu.

3.Move the cursor to DEL and press the CAM (SET) key.

This deletes the preset position and the PRESET NUMBER SET menu appears. The * mark on the right of the number disappears. Note: Your selected preset number is cancelled only in the SEQ and SORT mode. The previously set parameters (for PAN, TILT positions, etc.) are not changed. If you want to change

these parameters, you must set them again.

Setup menu

** SET UP MENU **

PRESET 1*

MAP

HOME POSITION OFF

SELF RETURN OFF

AUTO MODE OFF AUTO PAN KEY AUTO PAN DIGITAL FLIP ON LOCAL/REMOTE LOCAL SPECIAL1

CAMERA RS485 SET UP

Preset setting menu

PRESET NO. 1*

 

POSITION SET

 

 

PRESET ID

ON

 

ALC/MANUAL

ALC

 

DWELL TIME

10S

 

SCENE FILE

OFF

 

PRESET SPEED

••••••••

 

L

H

RET DEL

PRESET NUMBER SET menu

** PRESET NUMBER SET **

 

1

 

2

3

4

5

 

6

7

8

9

 

10

11

12

13

 

14

15

16

17

 

18

19

20

21

 

22

23

24

25

 

26

27

28

29

 

30

31

32

 

ID:DOOR

 

 

33-64

RET

 

 

Home Position Setting

(HOME POSITION)

1.To set a position number for the home position

Move the cursor to HOME POSITION and select a desired posi- tion number by moving the joystick to the right or left.

The factory default setting is OFF.

2.Select OFF if you are not using the home position function.

Note: This setting functions only when AUTO MODE is set to OFF.

Self Return Setting (SELF RETURN)

To set a time-out parameter for return to the home position

Move the cursor to SELF RETURN and select a return time by moving the joystick to the right or left.

The factory default setting is OFF. Return time changes as follows:

1MIN 2MIN3MIN 5MIN 10MIN

OFF 60MIN 30MIN20MIN

MIN stands for minute(s).

Note: The camera will return to the auto mode if that is set to SEQ, SORT, AUTO PAN or PATROL when a specific time has elapsed after a manual operation.

Setup menu

** SET UP MENU **

PRESET 1 MAP

HOME POSITION 15

SELF RETURN OFF

AUTO MODE OFF AUTO PAN KEY AUTO PAN DIGITAL FLIP ON LOCAL/REMOTE LOCAL SPECIAL1

CAMERA RS485 SET UP

Setup menu

** SET UP MENU **

PRESET 1 MAP

HOME POSITION OFF SELF RETURN 10MIN

AUTO MODE OFF AUTO PAN KEY AUTO PAN DIGITAL FLIP ON LOCAL/REMOTE LOCAL SPECIAL1

CAMERA RS485 SET UP

22

Image 21
Contents Operating Instructions Contents English Important Safety InstructionsPreface FeaturesCamera Cleaning PrecautionsPreset Data Uploading or Downloading Do not attempt to disassemble the cam- eraNever aim the camera at the sun Do not install the camera in places sub- ject to vibrationsIf Over Heat appears on the monitor screen ConsumablesConstruction Setup Menu SetupUp Switch Right Switch Left Switch Focus Switch Zoom SwitchSET Key CAM SET Key Down Switch Close CAM Setup F4 key Key for 2 sec Key for 2 secoPresetting Setup Menu DescriptionAuto Mode Auto Mode Home Position Home PositionDigital Flip Digital Flip Auto Pan Key Auto PAN KEYLocal/Remote LOCAL/REMOTE Special 1 MenuCamera Gain Control AGC Shutter Speed ShutterElectronic Sensitivity Enhancement Sens UP Synchronization SyncRS485 communication Setup Menu Display Setting ProceduresMenu Display Submenu DisplayPreset Menu Display PresettingPosition Setting Position SET To Set Panning/Tilting PositionsZOOM/FOCUS setting menu Pan OffsetTo Set the Lens Zoom and Focus Positions To Enter a New Preset ID Preset Identification Setting Preset IDTo Copy a Preset ID from Another Position To Change an Entered Preset IDTo Set a Display Position for a Preset ID Light Control Setting ALC/MANUALTo Return to the Preset Setting Menu Manual setting menuPreset Speed Setting Preset Speed Scene File Setting Scene FileTo Return to the Preset Number Set Menu To Return to the Setup MenuDeleting Preset Positions Home Position SettingSelf Return Setting Self Return Auto PAN setting menu Auto Mode Selection Auto ModeWhen the panning, tilting, zooming or focusing in the SEQ Digital Flip Setting Digital Flip Auto Pan Key SettingLocal/Remote Setting LOCAL/REMOTE Special 1 Menu Setting SpecialPrivacy Zone Privacy Zone Zone Scale setting menu Area Title Nesw setting menu When on Nesw is selectedProportional Pan/Tilt PROPO. P/T Area Title Area TitleDisplay Position setting menu Setting on UserDirection User setting menu Area Title EditingPatrol-learn and Patrol Play Patrol To Quit EditingArea Title menu Patrol-learn with a Controller not Having the Patrol Key Patrol-learn with a Controller Having the Patrol KeyPatrol Play with a Controller Having the Patrol Key Patrol Play with a Controller not Having the Patrol KeyAlarm Input/Output Alarm IN/OUT Alarm I/O submenuCNT-CLS 1, 2 Output Password Verification Password Lock Password LockNew Password Cleaning CleaningPreset Alarm Preset ALM Electronic Zoom EL-ZOOMImage Hold Image Hold To Display the Camera Setting Menu Camera SettingCamera setting menu Camera Identification Camera IDBacklight compensation menu Turns to white Blinking Shutter Speed Setting Shutter Gain Control AGCElectronic Sensitivity Enhancement Sens UP Line-lock Sync Mode LL Synchronization SyncSync menu Auto-Tracing White Balance Mode ATW1/ATW2 ATW fine adjustment menuWhite Balance White BAL AWC fine adjustment menu Automatic White Balance Control Mode AWCMotion detect menu Motion Detector Motion DETAuto Focus Setting AF Mode Special 2 Menu SPECIAL2 Black Burst Setting Burst BW To Restore the Camera Default Position RefreshCamera Resetting Camera Reset RS485 Setup Initial Camera Communication ParametersChanging the Camera Communication Parameters Delay Time Delay Time Alarm Data Alarm DataUnit Number Unit Number Sub Address SUB AddressPrecautions InstallationMounting the Camera Ceiling mountDisassembling the Camera PreparationsMounting the Bracket Waterproof Material X4 Screws Upper BaseRS485 Parameter Setup Setting the SwitchesUnit Number For Panasonic’s ProtocolSwitch position Unit Mounting the camera RS485 SettingAC Power Supply Connection How to Assemble the Cable with the Accessory ConnectorConnections Alarm in Connections Alarm OUT ConnectionsRS485 Connection System Connections Signal-to-noise ratio SpecificationsPower consumption Prevention of Blooming and SmearAccessories Optional AccessoriesWV-7176E Shortcuts AppendixRegional Offices N0202-1032 V8QA5996BN Imprimé au Japon