RS485 Setting

 

 

 

 

 

 

SW2

 

 

 

The 4-bit DIP switch is used for

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

RS485 termination.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

4-bit DIP SW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BP 1

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

ON

 

Termination ON

 

 

 

position

 

OFF

 

Termination OFF *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BP 2

BP 3

BP 4

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

ON

ON

ON

Half duplex (2 line)

 

position

OFF

OFF

OFF

Full duplex (4 line) *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

Defaults are marked with *.

BP stands for Bit Position.

Full duplex is not available in a daisy chain connection. (Panasonic system controllers only)

5.Mounting the camera

(1)Aim the “START” arrow at the bent por- tion of the leaf spring.

Bending

Leaf Spring

(2)Be sure to hook the fall prevention wire into the bracket.

Fall Prevention

Wire

(3)Fix the camera to the upper base.

Move the camera up so that its guide pins fit into the guide holes of the upper base.

Turn the camera counter-clockwise to the end, viewed from the bottom.

Fasten 3 screws.

X3 Screws

Upper Base

Enclosure

54

Image 53
Contents Operating Instructions Contents English Important Safety InstructionsPreface FeaturesCamera Cleaning PrecautionsPreset Data Uploading or Downloading Do not attempt to disassemble the cam- eraNever aim the camera at the sun Do not install the camera in places sub- ject to vibrationsIf Over Heat appears on the monitor screen ConsumablesConstruction Setup Menu SetupUp Switch Right Switch Left Switch Focus Switch Zoom SwitchSET Key CAM SET Key Down Switch Close CAM Setup F4 key Key for 2 sec Key for 2 secoPresetting Setup Menu DescriptionAuto Mode Auto Mode Home Position Home PositionDigital Flip Digital Flip Auto Pan Key Auto PAN KEYLocal/Remote LOCAL/REMOTE Special 1 MenuCamera Gain Control AGC Shutter Speed ShutterElectronic Sensitivity Enhancement Sens UP Synchronization SyncRS485 communication Setup Menu Display Setting ProceduresMenu Display Submenu DisplayPreset Menu Display PresettingPosition Setting Position SET To Set Panning/Tilting PositionsTo Set the Lens Zoom and Focus Positions ZOOM/FOCUS setting menuPan Offset To Enter a New Preset ID Preset Identification Setting Preset IDTo Copy a Preset ID from Another Position To Change an Entered Preset IDTo Set a Display Position for a Preset ID Light Control Setting ALC/MANUALTo Return to the Preset Setting Menu Manual setting menuPreset Speed Setting Preset Speed Scene File Setting Scene FileTo Return to the Preset Number Set Menu To Return to the Setup MenuSelf Return Setting Self Return Deleting Preset PositionsHome Position Setting Auto PAN setting menu Auto Mode Selection Auto ModeWhen the panning, tilting, zooming or focusing in the SEQ Digital Flip Setting Digital Flip Auto Pan Key SettingPrivacy Zone Privacy Zone Local/Remote Setting LOCAL/REMOTESpecial 1 Menu Setting Special Zone Scale setting menu Area Title Nesw setting menu When on Nesw is selectedProportional Pan/Tilt PROPO. P/T Area Title Area TitleDisplay Position setting menu Setting on UserDirection User setting menu Area Title EditingArea Title menu Patrol-learn and Patrol Play PatrolTo Quit Editing Patrol-learn with a Controller not Having the Patrol Key Patrol-learn with a Controller Having the Patrol KeyPatrol Play with a Controller Having the Patrol Key Patrol Play with a Controller not Having the Patrol KeyCNT-CLS 1, 2 Output Alarm Input/Output Alarm IN/OUTAlarm I/O submenu Password Verification Password Lock Password LockNew Password Cleaning CleaningImage Hold Image Hold Preset Alarm Preset ALMElectronic Zoom EL-ZOOM To Display the Camera Setting Menu Camera SettingCamera setting menu Camera Identification Camera IDBacklight compensation menu Turns to white Blinking Electronic Sensitivity Enhancement Sens UP Shutter Speed Setting ShutterGain Control AGC Sync menu Line-lock Sync Mode LLSynchronization Sync White Balance White BAL Auto-Tracing White Balance Mode ATW1/ATW2ATW fine adjustment menu AWC fine adjustment menu Automatic White Balance Control Mode AWCMotion detect menu Motion Detector Motion DETAuto Focus Setting AF Mode Special 2 Menu SPECIAL2 Camera Resetting Camera Reset Black Burst Setting Burst BWTo Restore the Camera Default Position Refresh Changing the Camera Communication Parameters RS485 SetupInitial Camera Communication Parameters Delay Time Delay Time Alarm Data Alarm DataUnit Number Unit Number Sub Address SUB AddressPrecautions InstallationMounting the Camera Ceiling mountDisassembling the Camera PreparationsMounting the Bracket Waterproof Material X4 Screws Upper BaseRS485 Parameter Setup Setting the SwitchesUnit Number For Panasonic’s ProtocolSwitch position Unit Mounting the camera RS485 SettingConnections AC Power Supply ConnectionHow to Assemble the Cable with the Accessory Connector RS485 Connection Alarm in ConnectionsAlarm OUT Connections System Connections Signal-to-noise ratio SpecificationsPower consumption Prevention of Blooming and SmearWV-7176E AccessoriesOptional Accessories Shortcuts AppendixRegional Offices N0202-1032 V8QA5996BN Imprimé au Japon