Patrol-learn with a Controller Having the PATROL Key

1.Press the PATROL LEARN key and PROGRAM key simultaneous- ly to start patrol-learn. The setup menu displays “LEARNING”, and the starting points are stored.

2.Operate patrol-learn manually. The operation data is stored.

3.To stop patrol-learn, press the PATROL STOP and PROGRAM key simultaneously.

Patrol-learn with a Controller not Having the PATROL Key

PATROL LEARN

LEARNING

1.Select patrol-learn in the setup menu, and then close the menu.

Starting points are stored and “LEARNING” appears on the monitor screen.

2.Operate patrol-learn manually.

3.Open the SET UP menu to stop learning.

Notes:

It is recommended to set PAN LIMIT to ON for patrol-learn. Otherwise PAN LIMIT is invalid in playback.

If the power fails during the patrol-learn mode, start the patrol-learn function again from the start- ing point.

LEARN also stops 30 seconds after starting if the memory is full.

Auto refreshing may be activated during the patrol play mode or the auto mode to calibrate the lens position.

Patrol Play with a Controller Having the PATROL Key

1.Press the PATROL PLAY key. The camera turns to the starting point and reproduces the operations stored in the memory. Iris operation is valid only in the playback mode.

2.Press the PATROL STOP key and PROGRAM key simultaneously to stop playback or press any man- ual operation key (e.g., PAN/TILT/ ZOOM/FOCUS) except the iris keys.

Patrol Play with a Controller not Having the PATROL Key

1.Select patrol play in the setup menu, and then close the menu. The camera turns to the starting point and the operations stored in memory are reproduced. Iris operation is valid only in the playback mode.

2.Open the SET UP menu, or press any manual operation key (e.g., PAN/TILT/ ZOOM/FOCUS) except the iris keys to stop playback.

Patrol Play with the AUTO PAN Key

1.If the PATROL PLAY function is assigned to the AUTO PAN key, press the AUTO PAN key to turn the camera back to the starting point and to reproduce the operation data stored in the memory.

2.To stop playback, press the PATROL STOP key and PROGRAM key simultaneously or any manual operation key (e.g., PAN/TILT/ZOOM/FOCUS) except the iris keys.

Notes:

During the patrol play mode, the camera movement may occasionally deviate from the entered rou- tine when the routine includes a move to a preset position. If this happens, re-enter the routine of manual operations for patrol-learn.

During the patrol play mode, black and white automatic switching does not work.

During the patrol play mode, when the power of the controller is turned on or off, the patrol play stops. In this case, press the PATROL PLAY key again. (If SELF RETURN is set to ON, the patrol play will start again after elapsing the setting return time.)

31

Image 30
Contents Operating Instructions Contents Important Safety Instructions EnglishFeatures PrefacePreset Data Uploading or Downloading PrecautionsCamera Cleaning Do not attempt to disassemble the cam- eraIf Over Heat appears on the monitor screen Do not install the camera in places sub- ject to vibrationsNever aim the camera at the sun ConsumablesConstruction Setup Setup MenuSET Key CAM SET Key Down Switch Focus Switch Zoom SwitchUp Switch Right Switch Left Switch Close CAM Setup F4 key Key for 2 sec Key for 2 secoAuto Mode Auto Mode Setup Menu DescriptionPresetting Home Position Home PositionLocal/Remote LOCAL/REMOTE Auto Pan Key Auto PAN KEYDigital Flip Digital Flip Special 1 MenuCamera Electronic Sensitivity Enhancement Sens UP Shutter Speed ShutterGain Control AGC Synchronization SyncRS485 communication Menu Display Setting ProceduresSetup Menu Display Submenu DisplayPosition Setting Position SET PresettingPreset Menu Display To Set Panning/Tilting PositionsZOOM/FOCUS setting menu Pan OffsetTo Set the Lens Zoom and Focus Positions To Copy a Preset ID from Another Position Preset Identification Setting Preset IDTo Enter a New Preset ID To Change an Entered Preset IDTo Return to the Preset Setting Menu Light Control Setting ALC/MANUALTo Set a Display Position for a Preset ID Manual setting menuTo Return to the Preset Number Set Menu Scene File Setting Scene FilePreset Speed Setting Preset Speed To Return to the Setup MenuDeleting Preset Positions Home Position SettingSelf Return Setting Self Return Auto Mode Selection Auto Mode Auto PAN setting menuWhen the panning, tilting, zooming or focusing in the SEQ Auto Pan Key Setting Digital Flip Setting Digital FlipLocal/Remote Setting LOCAL/REMOTE Special 1 Menu Setting SpecialPrivacy Zone Privacy Zone Zone Scale setting menu Proportional Pan/Tilt PROPO. P/T When on Nesw is selectedArea Title Nesw setting menu Area Title Area TitleDirection User setting menu Setting on UserDisplay Position setting menu Area Title EditingPatrol-learn and Patrol Play Patrol To Quit EditingArea Title menu Patrol Play with a Controller Having the Patrol Key Patrol-learn with a Controller Having the Patrol KeyPatrol-learn with a Controller not Having the Patrol Key Patrol Play with a Controller not Having the Patrol KeyAlarm Input/Output Alarm IN/OUT Alarm I/O submenuCNT-CLS 1, 2 Output Password Lock Password Lock Password VerificationCleaning Cleaning New PasswordPreset Alarm Preset ALM Electronic Zoom EL-ZOOMImage Hold Image Hold Camera setting menu Camera SettingTo Display the Camera Setting Menu Camera Identification Camera IDBacklight compensation menu Turns to white Blinking Shutter Speed Setting Shutter Gain Control AGCElectronic Sensitivity Enhancement Sens UP Line-lock Sync Mode LL Synchronization SyncSync menu Auto-Tracing White Balance Mode ATW1/ATW2 ATW fine adjustment menuWhite Balance White BAL Automatic White Balance Control Mode AWC AWC fine adjustment menuMotion Detector Motion DET Motion detect menuAuto Focus Setting AF Mode Special 2 Menu SPECIAL2 Black Burst Setting Burst BW To Restore the Camera Default Position RefreshCamera Resetting Camera Reset RS485 Setup Initial Camera Communication ParametersChanging the Camera Communication Parameters Unit Number Unit Number Alarm Data Alarm DataDelay Time Delay Time Sub Address SUB AddressMounting the Camera InstallationPrecautions Ceiling mountMounting the Bracket PreparationsDisassembling the Camera Waterproof Material X4 Screws Upper BaseSetting the Switches RS485 Parameter SetupFor Panasonic’s Protocol Unit NumberSwitch position Unit RS485 Setting Mounting the cameraAC Power Supply Connection How to Assemble the Cable with the Accessory ConnectorConnections Alarm in Connections Alarm OUT ConnectionsRS485 Connection System Connections Power consumption SpecificationsSignal-to-noise ratio Prevention of Blooming and SmearAccessories Optional AccessoriesWV-7176E Appendix ShortcutsN0202-1032 V8QA5996BN Imprimé au Japon Regional Offices