Panasonic WV-CW864 operating instructions Auto Pan Key Setting, Digital Flip Setting Digital Flip

Page 24

Auto Pan Key Setting

(AUTO PAN KEY)

This is used for assigning one of the following auto functions to the AUTO key on the controller. Pressing the AUTO key activates the assigned function after this setting.

Move the cursor to AUTO PAN KEY and select an auto function by moving the joystick to the right or left.

The factory default setting is AUTO PAN. Mode changes as follows:

AUTO PAN SEQ SORT

PATROL

AUTO PAN: Assigns the auto panning function to the key.

SEQ: Assigns the sequence function to the key.

SORT: Assigns the sort function to the key.

PATROL: Assigns the patrol play function to the key.

Note: Auto pan LED on the controller does not light if a function other than the auto pan function is assigned. The auto pan function cannot be stopped with the AUTO PAN key.

Setup menu

** SET UP MENU **

PRESET 1 MAP

HOME POSITION OFF

SELF RETURN OFF

AUTO MODE OFF AUTO PAN KEY AUTO PAN DIGITAL FLIP ON LOCAL/REMOTE LOCAL SPECIAL1

CAMERA RS485 SET UP

Digital Flip Setting (DIGITAL FLIP)

Move the cursor to DIGITAL FLIP and select ON or OFF by mov- ing the joystick to the right or left.

The factory default setting is ON.

OFF: Tilt range is limited from 0 ° to 90 °.

ON: The digital flip function allows the tilt angle to widen up to 180 °. The image on the monitor screen is flipped horizontally and vertically at the tilt angle of approx. 135 ° (If the camera is installed on a ceiling).

Note: Tilt range narrows from 180 ° to 90 ° if PAN LIMIT is set to ON.

Notes:

Digital flip functions while moving the joystick downwards. In case of moving the joystick to other directions, it does not function.

When OFF is selected for DIGITAL FLIP, the following operations are required to move the camera 180 ° vertically.

1)Move the joystick downwards to aim the camera down.

2)Move the joystick to the right or left to rotate the camera 180 ° horizontally.

3)Move the joystick upwards.

To set preset position directly from the WV-CU360, WV-CU550B or WV-CU161 System Controller, it is temporarily required setting both the electronic zoom function and digital flip function to OFF.

Tilt range setting is disabled between 90 ° and 180 °.

Setup menu

** SET UP MENU **

PRESET 1 MAP

HOME POSITION OFF

SELF RETURN OFF

AUTO MODE OFF AUTO PAN KEY AUTO PAN DIGITAL FLIP ON LOCAL/REMOTE LOCAL SPECIAL1

CAMERA RS485 SET UP

25

Image 24
Contents Operating Instructions Contents Important Safety Instructions EnglishFeatures PrefacePrecautions Camera CleaningPreset Data Uploading or Downloading Do not attempt to disassemble the cam- eraDo not install the camera in places sub- ject to vibrations Never aim the camera at the sunIf Over Heat appears on the monitor screen ConsumablesConstruction Setup Setup MenuFocus Switch Zoom Switch Up Switch Right Switch Left SwitchSET Key CAM SET Key Down Switch Close CAM Setup F4 key Key for 2 sec Key for 2 secoSetup Menu Description PresettingAuto Mode Auto Mode Home Position Home PositionAuto Pan Key Auto PAN KEY Digital Flip Digital FlipLocal/Remote LOCAL/REMOTE Special 1 MenuCamera Shutter Speed Shutter Gain Control AGCElectronic Sensitivity Enhancement Sens UP Synchronization SyncRS485 communication Setting Procedures Setup Menu DisplayMenu Display Submenu DisplayPresetting Preset Menu DisplayPosition Setting Position SET To Set Panning/Tilting PositionsZOOM/FOCUS setting menu Pan OffsetTo Set the Lens Zoom and Focus Positions Preset Identification Setting Preset ID To Enter a New Preset IDTo Copy a Preset ID from Another Position To Change an Entered Preset IDLight Control Setting ALC/MANUAL To Set a Display Position for a Preset IDTo Return to the Preset Setting Menu Manual setting menuScene File Setting Scene File Preset Speed Setting Preset SpeedTo Return to the Preset Number Set Menu To Return to the Setup MenuDeleting Preset Positions Home Position SettingSelf Return Setting Self Return Auto Mode Selection Auto Mode Auto PAN setting menuWhen the panning, tilting, zooming or focusing in the SEQ Auto Pan Key Setting Digital Flip Setting Digital FlipLocal/Remote Setting LOCAL/REMOTE Special 1 Menu Setting SpecialPrivacy Zone Privacy Zone Zone Scale setting menu When on Nesw is selected Area Title Nesw setting menuProportional Pan/Tilt PROPO. P/T Area Title Area TitleSetting on User Display Position setting menuDirection User setting menu Area Title EditingPatrol-learn and Patrol Play Patrol To Quit EditingArea Title menu Patrol-learn with a Controller Having the Patrol Key Patrol-learn with a Controller not Having the Patrol KeyPatrol Play with a Controller Having the Patrol Key Patrol Play with a Controller not Having the Patrol KeyAlarm Input/Output Alarm IN/OUT Alarm I/O submenuCNT-CLS 1, 2 Output Password Lock Password Lock Password VerificationCleaning Cleaning New PasswordPreset Alarm Preset ALM Electronic Zoom EL-ZOOMImage Hold Image Hold Camera Setting To Display the Camera Setting MenuCamera setting menu Camera Identification Camera IDBacklight compensation menu Turns to white Blinking Shutter Speed Setting Shutter Gain Control AGCElectronic Sensitivity Enhancement Sens UP Line-lock Sync Mode LL Synchronization SyncSync menu Auto-Tracing White Balance Mode ATW1/ATW2 ATW fine adjustment menuWhite Balance White BAL Automatic White Balance Control Mode AWC AWC fine adjustment menuMotion Detector Motion DET Motion detect menuAuto Focus Setting AF Mode Special 2 Menu SPECIAL2 Black Burst Setting Burst BW To Restore the Camera Default Position RefreshCamera Resetting Camera Reset RS485 Setup Initial Camera Communication ParametersChanging the Camera Communication Parameters Alarm Data Alarm Data Delay Time Delay TimeUnit Number Unit Number Sub Address SUB AddressInstallation PrecautionsMounting the Camera Ceiling mountPreparations Disassembling the CameraMounting the Bracket Waterproof Material X4 Screws Upper BaseSetting the Switches RS485 Parameter SetupFor Panasonic’s Protocol Unit NumberSwitch position Unit RS485 Setting Mounting the cameraAC Power Supply Connection How to Assemble the Cable with the Accessory ConnectorConnections Alarm in Connections Alarm OUT ConnectionsRS485 Connection System Connections Specifications Signal-to-noise ratioPower consumption Prevention of Blooming and SmearAccessories Optional AccessoriesWV-7176E Appendix ShortcutsN0202-1032 V8QA5996BN Imprimé au Japon Regional Offices