(7) White Balance (WHITE BAL)

You can select either of three modes shown below for white balance adjustment:

Auto-Tracing White Balance (ATW1)

In this mode, the color temperature is monitored continuously and thereby white balance is set auto- matically. The color temperature range for the proper white balance is approx. 2 600 - 6 000 K. Proper white balance may not be obtained under the following conditions:

1.The color temperature is out of the 2 600 - 6 000 K range.

2.When the scene contains mostly high color temperature (bluish) objects, such as a blue sky.

3.When the scene is dim.

In these cases, select the AWC mode.

Auto-Tracing White Balance (ATW2)

This mode enables the camera to trace the white balance when it is used in an area lit by sodium lamps.

• Automatic White Balance Control (AWC)

In this mode, accurate white balance is obtained within a color temperature range of approx. 2 300 - 10 000 K.

See page 42 for the setting.

(8) Motion Detector (MOTION DET)

The motion detector detects motion in a scene by monitoring changes in the brightness level. You can select the sensitivity level for the motion on the setup menu.

When the camera detects motion, it sends the alarm signal to the external equipment and stops at its position for the preset dwell time.

See page 43 for the setting.

(9) Auto Focus (AF MODE)

The camera adjusts the focus automatically by sensing the center of the picture. S, M and L stand for the size of the sensing area: Small, Middle and Large.

See page 44 for details.

MANUAL S, M, L: Auto-focus is activated only when the AF key on the controller is pressed.

AUTO S, M, L: Auto-focus is activated automatically while a manual pan, tilt or zoom operation is per- formed.

Note: If SENS UP is set to ON except x2 FIX or x2 AUTO, the AUTO (S/M/L) mode is disabled and the MANUAL (S/M/L) mode is automatically selected.

(10)Special 2 Menu (SPECIAL2)

This menu allows you to adjust and set up the following items and functions: chroma level, aperture level, pedestal level, black and white function, digital noise reduction function and refresh function. You can also reset your parameters to the factory default settings.

See page 45 for the setting.

RS485 communication

Refer to the following pages for the communication parameter settings.

Full/Half duplex (page 54)

• Camera units (96 units max.) (page 52)

Transmission Speed (2 400 - 19 200 bps) (page 48)

• Termination ON/OFF (page 54)

Parity bit, Stop bit, Flow control (page 48)

• Reset parameters (page 51)

Wait time, Delay time, Alarm output (page 48)

 

15

Image 14
Contents Operating Instructions Contents Important Safety Instructions EnglishFeatures PrefacePreset Data Uploading or Downloading PrecautionsCamera Cleaning Do not attempt to disassemble the cam- eraIf Over Heat appears on the monitor screen Do not install the camera in places sub- ject to vibrationsNever aim the camera at the sun ConsumablesConstruction Setup Setup MenuSET Key CAM SET Key Down Switch Focus Switch Zoom SwitchUp Switch Right Switch Left Switch Close CAM Setup F4 key Key for 2 sec Key for 2 secoAuto Mode Auto Mode Setup Menu DescriptionPresetting Home Position Home PositionLocal/Remote LOCAL/REMOTE Auto Pan Key Auto PAN KEYDigital Flip Digital Flip Special 1 MenuCamera Electronic Sensitivity Enhancement Sens UP Shutter Speed ShutterGain Control AGC Synchronization SyncRS485 communication Menu Display Setting ProceduresSetup Menu Display Submenu DisplayPosition Setting Position SET PresettingPreset Menu Display To Set Panning/Tilting PositionsTo Set the Lens Zoom and Focus Positions ZOOM/FOCUS setting menuPan Offset To Copy a Preset ID from Another Position Preset Identification Setting Preset IDTo Enter a New Preset ID To Change an Entered Preset IDTo Return to the Preset Setting Menu Light Control Setting ALC/MANUALTo Set a Display Position for a Preset ID Manual setting menuTo Return to the Preset Number Set Menu Scene File Setting Scene FilePreset Speed Setting Preset Speed To Return to the Setup MenuSelf Return Setting Self Return Deleting Preset PositionsHome Position Setting Auto Mode Selection Auto Mode Auto PAN setting menuWhen the panning, tilting, zooming or focusing in the SEQ Auto Pan Key Setting Digital Flip Setting Digital FlipPrivacy Zone Privacy Zone Local/Remote Setting LOCAL/REMOTESpecial 1 Menu Setting Special Zone Scale setting menu Proportional Pan/Tilt PROPO. P/T When on Nesw is selectedArea Title Nesw setting menu Area Title Area TitleDirection User setting menu Setting on UserDisplay Position setting menu Area Title EditingArea Title menu Patrol-learn and Patrol Play PatrolTo Quit Editing Patrol Play with a Controller Having the Patrol Key Patrol-learn with a Controller Having the Patrol KeyPatrol-learn with a Controller not Having the Patrol Key Patrol Play with a Controller not Having the Patrol KeyCNT-CLS 1, 2 Output Alarm Input/Output Alarm IN/OUTAlarm I/O submenu Password Lock Password Lock Password VerificationCleaning Cleaning New PasswordImage Hold Image Hold Preset Alarm Preset ALMElectronic Zoom EL-ZOOM Camera setting menu Camera SettingTo Display the Camera Setting Menu Camera Identification Camera IDBacklight compensation menu Turns to white Blinking Electronic Sensitivity Enhancement Sens UP Shutter Speed Setting ShutterGain Control AGC Sync menu Line-lock Sync Mode LLSynchronization Sync White Balance White BAL Auto-Tracing White Balance Mode ATW1/ATW2ATW fine adjustment menu Automatic White Balance Control Mode AWC AWC fine adjustment menuMotion Detector Motion DET Motion detect menuAuto Focus Setting AF Mode Special 2 Menu SPECIAL2 Camera Resetting Camera Reset Black Burst Setting Burst BWTo Restore the Camera Default Position Refresh Changing the Camera Communication Parameters RS485 SetupInitial Camera Communication Parameters Unit Number Unit Number Alarm Data Alarm DataDelay Time Delay Time Sub Address SUB AddressMounting the Camera InstallationPrecautions Ceiling mountMounting the Bracket PreparationsDisassembling the Camera Waterproof Material X4 Screws Upper BaseSetting the Switches RS485 Parameter SetupFor Panasonic’s Protocol Unit NumberSwitch position Unit RS485 Setting Mounting the cameraConnections AC Power Supply ConnectionHow to Assemble the Cable with the Accessory Connector RS485 Connection Alarm in ConnectionsAlarm OUT Connections System Connections Power consumption SpecificationsSignal-to-noise ratio Prevention of Blooming and SmearWV-7176E AccessoriesOptional Accessories Appendix ShortcutsN0202-1032 V8QA5996BN Imprimé au Japon Regional Offices