To Quit Editing
•To return to the AREA TITLE menu, move the cursor to RET, and press the CAM (SET) key.
•To cancel one area title, move the cursor to RESET in the AREA TITLE menu, and press the CAM (SET) key.
•To return to the SPECIAL 1 menu, move the cursor to RET, and press the CAM (SET) key.
•To erase all the area titles, move the cursor to RESET in the AREA TITLE (USER) selection menu, and press the CAM (SET) key.
Notes:
•An area title appears under the camera ID if both are set in the same position. If the setting is different, they appear in the area title position.
•In case of sharing a common subject in a scene of other cam- era number, the nearest area title appears while the camera direction deviates within 45 ° from the set position. If two or more area numbers are set in the same position, the title of the highest number appears.
●Patrol-learn and Patrol Play (PATROL)
A routine of manual operations can be stored for 30 seconds at the maximum and reproduced repetitively.
1.Set the following parameters for the
•PAN/TILT/ZOOM/FOCUS
•IRIS
•SHUTTER
•AGC
•SENS UP
•WHITE BALANCE
•IMAGE HOLD
•AREA TITLE
•DIGITAL FLIP
•PRIVACY ZONE
•CAMERA ID
•PROPO.PT
•PAN LIMIT
•BURST
•CLEANING
After starting the
•PAN/TILT/ZOOM/FOCUS operation
•IRIS operation
•Preset positioning
2.Open the SET UP menu and move the cursor to SPECIAL 1. For PATROL, select LEARN, PLAY or STOP by moving the joystick to the right or left.
The factory default setting is STOP.
LEARN: A series of manual operations is stored.
PLAY: Stored operations are reproduced.
STOP: LEARN or PLAY is not activated.
AREA TITLE menu
AREA TITLE 1* 0123456789 ABCDEFGHIJKLM NOPQRSTUVWXYZ ().,'":;&#!?=
SPACE
POSI RET RESET
................
Display Position setting menu
FLOOR 1
NORTH
Special 1 menu
** SPECIAL 1 **
PRIVACY ZONE | OFF(ENB) | |
PROPO.P/T | ON | |
AREA TITLE | ON(USER) | |
PATROL | STOP |
|
ALARM IN/OUT |
|
|
PASSWORD LOCK | OFF | |
CLEANING | OFF | |
ON | ||
PRESET ALM | OFF | |
IMAGE HOLD | OFF | |
RET |
|
|
30