1)Unplug the iron and empty the water tank.
2)Press the steam button so it is lifted.
3)Remove carefully (some water may now leak from the sole plate).
4)Do not touch the anticalc valve.
5)Immerse in vinegar (not vinegar essence) or lemon juice until the lime becomes soft.
6)Use a
7)Rinse under running water.
8)
9)Press to check the steam on/off function.
Note: the iron must never be used without the steam button.
I Decalcifying/ anticalc system
When scale particles come out of the steam vents or when the steam development is insufficient even after cleaning the anticalc valve, you should clean the steam chamber as follows:
1)Make sure the steam button is in its lower position.
2)– 3) Fill water into the tank, connect to the mains and select the «•••» temperature setting.
4)– 5) Wait until the pilot light turns off. Unplug the iron.
6)– 7) Hold the iron over a sink, then press the steam button so it is lifted, carefully pull it up, turn it and rest it in this position.
Caution: When the steam button is pulled up, hot water and steam will come out from the sole plate.
8)Push back the steam button until it catches in the lower position.
9)– 10) Fill water into the tank, connect to the mains and select the «•••» temperature setting.
11)– 13) When the pilot light goes off, press the power shot button 4 times to rinse the iron. Disconnect the iron and wait for the sole plate to cool off, then clean it as described above in section «G».
Note: the iron must never be used without the steam button.
J Trouble-shooting guide
Problem Remedy
Drops | Turn the steam regulator |
coming out | |
of the steam | reduce the steam or |
vents | press the steam button |
| to turn the steam off. |
| Take longer intervals |
| when pressing the power |
| shot button. |
| Select a higher tempera- |
| ture setting. |
No steam | Press the steam button |
at all | so that it is lifted. |
Less steam | Clean the anticalc valve |
develops or | (see «F»). |
no steam at all |
|
Calcium parti- Decalcify the steam
cles coming chamber (see «G»). through the
steam vents
Subject to change without notice.
This product conforms to the Euro- pean Directives EMC 89/336/EEC and Low Voltage 73/23/EEC.
At the end of the product's useful life, please dispose of it at appropriate collection points provided in your country.
10