Johnson Hardware IB-412 R01 instruction manual Applications, Installation instructions, General

Page 9

Johnson Pump Marine Toilet, Manual

Applications

Johnson Pump Comfort and Compact bowl manually operated marine toilets can be installed in both power and sailing craft, either above or below the waterline, for use on sea, river, lake or canal.

The waste can be discharged either overboard (please have in mind national or local restrictions), or into a treatment system or into an on-board holding tank.

Note: Johnson Pump manual toilets are designed specifically for marine use. Consult your Johnson Pump retailer for advice about possible non-marine applications.

Features

Design

Flexible hole pattern on the base, for easy substitution with the most common toilets on the market

Reversible pump mounting allows re-assembly for left hand operation by installer

Self-priming, double acting piston pump

Piston rod guide in brass for increased service life

Strong swirl action for efficient flushing

Smooth design for easy cleaning

Ergonomic handle

Spring assisted top valve closure for easier priming

Constant 38mm (1 1/2") bore waste path minimizes blockages

Double check-valves at full 38mm (1 1/2") bore prevent back flow

Multi-angle outlet for various installations

Accessible mounting points for faster installation

Standard fastenings, logic located, no need for special tools

Double sealed base plug for winter drain and easy cleaning access

Material

Premium baked enamel painted wooden seat and cover

Hygienic white ceramic bowl for ease of cleaning

Pump and base moulded in ABS or polypropylene, stainless steel fastenings, brass weights and neoprene seals and gaskets

Performance

Self priming, dry, height 1m (3ft)

Discharge height 3m (9ft)

Dimensions

• Dimensional Drawing on the page x.

Installation instructions, General

Through hull fittings:

You need:

19 mm. (3/4”) bore seacock for the flushing water inlet and, if you are discharging overboard, a 38 mm. (1 1/2”) bore seacock for the waste outlet.

Keep to the seacock manufacturer’s instructions concerning materials and methods of installation

Ensure that the inlet seacock is positioned where it will be below the waterline at all times when the craft is under way and also ensure that any outlet seacock is both aft of, and higher than the inlet seacock

Pipework -selection of the correct method:

You must select the correct installation method for the inlet pipework from 2 possibilities and for the outlet pipework from 4 possibilities, according to whether the toilet is above or below the waterline and to whether it discharges the waste overboard or into an on-board holding tank.

General instructions for all possible installations

You need:

Spiral reinforced smooth bore flexible hose for both the 19 mm.

(3/4") internal diameter inlet and the 38 mm (1 1/2") internal diameter outlet hose

Stainless steel hose clip

secure the hose runs so that the hoses cannot move, nor exert any leverage action on the hosetail fittings to which they are connected, as this may cause adjacent joints to leak.

avoid sharp bends in the hoses since this might cause them to become kinked

keep all pipework lengths as short as possible while you are carrying out these operations Unnecessary inlet or outlet hose lengths just make the toilet harder to pump.

Tip: Should it be difficult to fit the hose onto the hose tails of the toilet or the sea cocks, soften the hose by dipping its end in hot water

Caution:

DO NOT APPLY FLAME TO HOSES

DO NOT APPLY FLAME OR HEAT TO THE PLASTIC HOSE TAILS OF THE TOILET

DO NOT APPLY SEALING COMPOUNDS TO ANY HOSE CONNECTION

Secure all hose ends to the hose tails with preferably two stainless steel clips, ensuring that all inlet connections are airtight and that all outlet connections are watertight.

The discharge elbow may be rotated 360 deg. to suit your in- stallation. Always slacken the 2 securing screws, adjust the discharge elbow to the required position and retighten the 2 securing screws before connecting the hose to it

Caution:

FAILURE TO FOLLOW THIS PROCEDURE MAY CAUSE LEAKS BE- TWEEN THE ELBOW AND THE PUMP CYLINDER

Pipework – Inlet, 2 alternatives

Alternative 1:

Toilet below the waterline

You must use a 19 mm (3/4”) Vented Loop fitting.

Run the inlet hose by the most direct way from the inlet seacock to the flushing pump inlet tail.

Remove the white hose supplied with the toilet which connects the flushing pump outlet tail to the bowl elbow

Using a spanner, rotate the intake seal so that the elbow points upwards

Replace the white hose with a longer length of 19 mm internal diameter hose and position it in a way that its point is at least

20 cm (8”) above the highest possible waterline and fit the vented loop at that highest point

Caution:

DO NOT POSITION THE VENTED LOOP BETWEEN THE INLET SEA- COCK AND THE FLUSHING PUMP INLET, as it will make the flushing pump difficult or harder to prime, and could prevent it from working at all.

English



Image 9
Contents AquaT Marine Toilet Garanti WarrantyGarantie GarantíaInstallationsanvisningar, allmänt Allmänna instruktioner för samtliga installationerTillämpningar Rördragning Inlopp, 2 alternativAlternativ Toalett över vattenlinjen Rördragning Utlopp, 4 alternativAlternativ Alternativ Toalett över vattenlinjen och tömning överbordSäkerhet InstallationsanvisningInledning PlaceringUnderhållsinstruktioner DriftanvisningarMontering InledningByte av tätning Service Förberedelse för vinterrustningVinterrustning ÖversynReservdelar och referenslista Dimensioner & ViktInstallation instructions, General ApplicationsPipework Inlet, 2 alternatives Pipework Outlet, 4 alternatives TestingAlternative Toilet above the waterline AlternativeSafety Installation InstructionsIntroduction LocationMaintenance Instructions Operating InstructionsIntroduction Overhaul WinterizationSpare Parts & Reference guide Installationsanweisungen, Allgemeines AnwendungenRohrleitung Einlauf, 2 Möglichkeiten Möglichkeit Toilette über die Wasserlinie Rohrleitung Auslauf, 4 MöglichkeitenMöglichkeit PrüfenEinleitung MontageanweisungenMontageort MontageBetriebsanweisungen WartungsanweisungenEinleitung Dichtung ersetzen Winterfest machenInstandsetzung Ersatzteile und Bezug Abmessungen und GewichteTuyauterie Prise d’eau, 2 alternatives Instructions d’installation, GénéralitésAlternative Toilettes au-dessus de la ligne de flottaison Tuyauterie Evacuation, 4 alternativesEssais Vous pouvez utiliser un clapet de non-retour de 19 mm 3/4Emplacement Instructions Pour L’INSTALLATIONSecurite Tuyauterie Desserree Bord de la cuvette en dessous de la ligne de flottaisonPremière utilisation Instructions D’UTILISATIONUtilisation normale NettoyageService d’entretien Préparation pour l’hivernage Instructions Pour LA MaintenanceRemplacement du dispositif d’étanchéité Remise en serviceVenablement serré Dimensions & PoidsPièces de rechange & Guide de référence Fixer le cylindre à la base des toilettes ÉtriersAplicaciones Instrucciones de instalación, GeneralTuberías Entrada, 2 alternativas Alternativa Aseo por encima de la línea de flotación Tuberías Salida, 4 alternativasAlternativa PruebasSeguridad Instrucciones DE InstalaciónIntroducción UbicaciónInstructiones DE Mantenimiento Instrucciones DE FuncionamientoMontaje IntroducciónPreparación para el invierno Remplazo del selladoRevisión y Puesta a punto PrecauciónPiezas de repuesto & Guía de referencia Dimensiones & PesoIstruzioni di installazione, Generale ApplicazioniTubazioni Entrata, 2 alternative Tubazioni Sbocco, 4 alternative TestSicurezza Introduzione Istruzioni DI InstallazioneCollocazione MontaggioIstruzioni DI Funzionamento Istruzioni PER LA ManutenzioneIntroduzione Sostitizione delle guarnizioni Istruzioni di servizio Preparazione per la messa a riposoMessa a riposo RevisioneParti di Ricambio e Guida di Riferimento Dimensioni e pesoPage Johnson Pump AB