MAINTENANCE
ELECTRONIC IGNITION SYSTEM OPERATIONS
If the Electronic Ignition System fails to ignite, be sure there is gas flow by attempting to match light your burners. Refer to “MAIN BURNER MANUAL IGNITION”. If match lighting is successful, the problem lies is the electronic ignition.
WARNING: All gas controls and supply valves should be in the OFF position.
•Verify that the AA battery (alkaline only) is in good condition and installed correctly
(1). Some batteries have a plastic protective wrap around them. This plastic must be removed. Do not confuse this plastic with the battery label.
•Make sure the ignition wires are attached to igniter module properly. Refer to the
“IGNITER MODULE WIRE GUIDE” below.
•Make sure the ceramic igniter assembly is fully positioned into burner tube igniter channel (2). If properly positioned, you will hear a snap (3).
•Make sure the Electronic Ignition button is working by listening and looking for sparks at burner.
If the Electronic Ignition System still fails to light, contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®. ◆
1
2
3
IGNITER MODULE WIRE GUIDE 310
1 2
A C B
4 3
1
3
4
|
| 2 |
|
| |
Wire End & Terminal Color |
| Burner Tube |
Black (1) |
| Left Burner (A) |
Yellow (2) |
| Right Burner (B) |
Blue (3) |
| Center Burner (C) |
Green (Ground) (4) |
| Center Burner (C) |
WWW.WEBER.COM® 21