A&D AD-4405 manual Description of Panels and symbols, Front Panel Description

Page 10

4. Description of Panels and symbols

4.1.1.Front Panel Description

1

2

3

4

8

9

567

10

N

Name

 

Description

 

o.

 

 

 

 

 

 

1

STABLE

Indicates when the display is stable.

 

2

NET

Indicates when the display is the net weight.

3

ZERO

Indicates when the display weight is in the Zero range.

4

Annunciator

lndicates various weighing status or functional selection.

 

PT

Indicates when PRESET TARE value is being used.

 

READY

Indicates the state of comparison or batching.

 

M+ (Accumulation)

Indicates when there is a result of addition or accumulation.

 

1,2,3(Triangle)

Depending on the function selected, Indicates various states.

5

MAIN display

Displays the weight, accumulation data or setting parameters.

6

UNIT part

Unit used to weigh.

 

7

HI/OK/LO

Indicates the results of comparison.

 

8

Capacity label

Capacity and division (this label is included in the accessories).

9

Key switches

Selects the display, settings or data output.

 

CODE key

The key to select the code memory.

 

 

SAMPLE key

The key to set the unit weight for the counting function.

 

SETPOINT key

The key to set the comparator value.

 

 

PT key

The key to set the PRESET TARE value.

 

 

TOTAL key

The key to display the total weight.

 

 

M+ key

The key to display the total weight.

 

 

START key

The key to start comparison / batch weighing.

 

STOP key

The key to stop comparison / batch weighing.

 

FEED key

The key to feed the paper of the optional Built-in Printer.

 

MODE key

The key to switch unit used to weigh.

 

 

0 – 9 key

The key to input any numerical settings.

 

 

A – F key

Used to enter setting values (press NET/GROSS key at a time).

4. Description of Panels and symbols

Page 8

AD-4405 Weighing Indicator

Image 10
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance with FCC Rules ComplianceCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Adjustment of the Load Cell Output Verifying Load Cell Output and Input SensitivityInstalling an Option Board Description of Panels and symbols Front Panel DescriptionOther Displays and Symbols Rear Panel DescriptionSupplemental accessories for printer Accessories and optionsStandard accessories OptionsItems of Calibration Mode CalibrationCalibration Procedure Configuring a Weighing InstrumentSpecifying the Resolution, Decimal Point Position and Format Specifying the Range and UnitSpecifying the Weighing Range of the First Range Specifying the Second Range ResolutionTo Get Stabilized Data Specifying the Second Range CapacityZero Calibration Span CalibrationExiting the Calibration Mode Weighing Range Function Setting the Division and Range Digital Linearization FunctionGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Changing the Function Settings FunctionsFunctions OFFZERO+TARE = CAL EXT2 EXT1EXT3 Comparator Data Output Current Loop Output Serial Interface YY/MM/DD MM/DD/YY DD/MM/YYPrint Format CF-Functions Weighing Tare Digital Input Preset TareTare Clearing TarePreparation and Specifications AccumulationDisplay and Operation Parameter Using Code Memory Code MemoryWeight Check Mode ComparisonHI, OK Condition formula for ComparisonLO, OK Setting Order and Display for Weight Check Mode Setting the Upper/Lower Limit ValuesMode F22 = 7 Check weighing Setpoint ComparisonDescription of Input parameters and Outputs Output and ConditionStart F22 = 9 Check weighing 3Loss in weightSimple Batch Weighing CompletionToward the Zero band Setting the Parameters of Setpoint ComparisonReturns to Zero band Display and the Data Output of Hold and Average Setting the Hold FunctionsHold Function Relations to the Other FunctionsTARE, ZERO, SETPOINT, Total Key input and command in the hold stateConditions of the Average and Release MT, MZ, HCUnit Weight Registration Using the Counting FunctionCounting Function Key to register the unit weight and return to the piece 13.1 Time and Date Functions Calendar / ClockYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Installing the Printer Paper Special roll paper Replacing the Ink Ribbon15.1 Data Output / Print Mode Common Printer and Data Output ItemsData Number Interval Data Output / PrintSetting the Interval Time Interval Data Output / Print outputCircuit and Pin Connection 16.1 SpecificationsRS-232C Interface Bit FormatData Format FiguresCommand Format Explanation of CommandsCommands to Request Data Commands to Control the Indicator Changing the Weight Unit Changing the Code MemorySet the Unit Weight for Counting Mode Commands to Set ParametersSet the Preset Tare Set the Limit/Setpoint ValueStart Averaging to Hold Commands for the Hold FunctionCommands to Set the Data Output/ Print Format UFC Release the Hold DataUFC Commands UFC Command Parameters’$AN$TL$LF$LF $DLSF1,$ID$DN$CR$LF$GR$UT$CR$LF PF2,$DT$TM$LF$AN$SP$TL$LFCOM RS-422/RS-485, Relay OutputOP-03TRM CircuitSwitching Between RS-422/RS-485 DC50V Relay Output & Control Input OP-05Circuits Settings Specifications19 -20mA Analog Output OP-07 CL1 Current Loop Output OP-08CL2 Current Loop Output Data FormatDigital Section SpecificationsAnalog Input and A/D Conversion InterfaceDimensions GeneralMemo Memo Memo