A&D AD-4405 manual $Dl, SF1,$ID$DN$CR$LF$GR$UT$CR$LF, ’$An$Tl$Lf$Lf, PF2,$DT$TM$LF$AN$SP$TL$LF

Page 67

$DL

Inserting a DeLay time (0.1 second step)

 

Example: DL10 : 1.0 second delay

Strings

Output or print specified strings enclosed by a single quotation (’).

itself is described using three single quotations; ’’’. Example: ’A & D’ ’This is a sample of ’’’ .’

Set data bit = 8 bit if using the 8 bit characters.

Hexadecimal

Control code of the printer etc. preceded by #.

2 characters proceeded by # is hexadecimal code. Example: #09, #7C

The #FF code can not be used because it is used for internal control.

Example

SF1,$ID$DN$CR$LF$GR$UT$CR$LF

Serial output data format 1, ID number, data number, carriage return and line feed, Gross weight, unit, carriage return and line feed.

SF2,’ Welcome to A & D’$LF’Total weight

’$AN$TL$LF$LF

Serial output data format 2, the strings ’

Welcome to A & D’ and line feed,

the strings ’Total weight ’ accumulation count, total weight, and 2 sets of line feed.

PF2,$DT$TM$LF$AN$SP$TL$LF

Date and time

Line feed

Accumulation number

Total weight

Line feed

AD-4405 Weighing Indicator

Page 65

16.4. UFC Command

Image 67
Contents Weighing Indicator This manual and Marks Contents Setting the Parameters of Setpoint Comparison Compliance with FCC Rules ComplianceCompliance with European Directives Introduction Installation and Precautions Installation and PrecautionsLoad Cell Connections Verifying Load Cell Output and Input Sensitivity Adjustment of the Load Cell OutputInstalling an Option Board Front Panel Description Description of Panels and symbolsRear Panel Description Other Displays and SymbolsOptions Accessories and optionsStandard accessories Supplemental accessories for printerCalibration Items of Calibration ModeConfiguring a Weighing Instrument Calibration ProcedureSpecifying the Range and Unit Specifying the Resolution, Decimal Point Position and FormatSpecifying the Second Range Capacity Specifying the Second Range ResolutionTo Get Stabilized Data Specifying the Weighing Range of the First RangeSpan Calibration Zero CalibrationExiting the Calibration Mode Weighing Range Function Digital Linearization Function Setting the Division and RangeGravity Compensation Function Gravity Acceleration Table Calibration Error Code List Functions Changing the Function SettingsOFF FunctionsZERO+TARE = CAL EXT2 EXT1EXT3 Comparator Data Output Current Loop Output Serial Interface DD/MM/YY YY/MM/DD MM/DD/YYPrint Format CF-Functions Clearing Tare Digital Input Preset TareTare Weighing TareAccumulation Preparation and SpecificationsDisplay and Operation Parameter Code Memory Using Code MemoryComparison Weight Check ModeHI, OK Condition formula for ComparisonLO, OK Setting Order and Display for Weight Check Mode Setting the Upper/Lower Limit ValuesMode Output and Condition Setpoint ComparisonDescription of Input parameters and Outputs F22 = 7 Check weighingWeighing Completion F22 = 9 Check weighing 3Loss in weightSimple Batch StartToward the Zero band Setting the Parameters of Setpoint ComparisonReturns to Zero band Relations to the Other Functions Setting the Hold FunctionsHold Function Display and the Data Output of Hold and AverageMT, MZ, HC Key input and command in the hold stateConditions of the Average and Release TARE, ZERO, SETPOINT, TotalUnit Weight Registration Using the Counting FunctionCounting Function Key to register the unit weight and return to the piece 13.1 Time and Date Functions Calendar / ClockYY/MM/DD Setting Time and Date Corrected date is as follows 05 05 Internal Printer OP-06 Replacing the Ink Ribbon Installing the Printer Paper Special roll paperCommon Printer and Data Output Items 15.1 Data Output / Print ModeInterval Data Output / Print Data NumberInterval Data Output / Print output Setting the Interval TimeBit Format 16.1 SpecificationsRS-232C Interface Circuit and Pin ConnectionFigures Data FormatExplanation of Commands Command FormatCommands to Request Data Commands to Control the Indicator Changing the Code Memory Changing the Weight UnitSet the Limit/Setpoint Value Commands to Set ParametersSet the Preset Tare Set the Unit Weight for Counting ModeRelease the Hold Data Commands for the Hold FunctionCommands to Set the Data Output/ Print Format UFC Start Averaging to HoldUFC Command Parameters UFC CommandsPF2,$DT$TM$LF$AN$SP$TL$LF $DLSF1,$ID$DN$CR$LF$GR$UT$CR$LF ’$AN$TL$LF$LFCircuit RS-422/RS-485, Relay OutputOP-03TRM COMSwitching Between RS-422/RS-485 DC50V Relay Output & Control Input OP-05Circuits Settings Specifications19 -20mA Analog Output OP-07 CL1 Current Loop Output OP-08CL2 Data Format Current Loop OutputInterface SpecificationsAnalog Input and A/D Conversion Digital SectionGeneral DimensionsMemo Memo Memo